Number or Letter

3

B

E

Q

Explanation

Number of 

compartments in 

appliance

No Media

No Media

Fine Mesh Resin

Letter

Media Type

Letter

Media Type

A

Empty

M

Ultra-fil

B

Chlorostat

N

Manganese Greensand

C

A554 Nitrate Resin

P

SulfurStat and 6 lb. Ultra-fil

D

Tannin Resin

Q

Fine Mesh Resin and 2 lb. Bacteriostat

E

PC Carbon (Activated Carbon)

R

Filter Ag

F

Multi-Grade

S

Calcite/Corosex

J

Calcite and 6 lb. Ultra-fil

X

Fine Mesh Resin

K

BIRM and 6 lb. Ultra-fil

Model

Rated Efficiency

Salt Dosage

Capacity at That Dosage

3MAQ

5,200 grains/lb (738 grams/kg)

1.1 lb (0.5 kg)

5,700 grains (369 grams)

3BAQ

5,400 grains/lb (772 grams/kg)

1.1 lb (0.5 kg)

6,000 grains (389 grams)

3BEQ

5,400 grains/lb (772 grams/kg)

1.1 lb (0.5 kg)

6,000 grains (389 grams)

2MXQ

5,400 grains/lb (772 grams/kg)

1.7 lb (0.8 kg)

9,300 grains (603 grams)

2AMQ

5,200 grains/lb (738 grams/kg)

1.1 lb (0.5 kg) 

5,700 grains (369 grams)

2APQ

3,900 grains/lb (569 grams/kg)

6.2 lb (2.8 kg) 

24,600 grains (1,594 grams)

Reading Model Numbers

Specifications

Efficiency Statements

For All Models:

Use clean white pellet, cube-style, or solar salt. 

Drain Line (Minimum I.D.) 1/2-inch (1.3 cm)

Height–inches (cm) 38–1/4 (97)

Salt storage capacity–lb (kg) 200 (90)

Electrical rating: 115V, 60 cycle

Valve Inlet/Outlet–1 inch

Water Temperature (Min-Max) 40°–120°F (4°–49°C)

Floor Space–inches (cm) 15 x 30 (38 x 76)

Brine & Rinse total–gpm (L/min) 0.75 (2.5) 

Brine Draw–gpm (L/min) 0.25 (0.9)

Rinse–gpm (L/min) 0.5 (1.5) 

Iron reduction to 0.3 ppm or less (Not certified by WQA.)

*Listed with the U.S. EPA as a Bacteriostatic Device U.S. EPA # 54369-

OH-001. Not certified by WQA

1

  Regeneration every 96 hours is required when iron is present in the raw 

water supply unless noted otherwise. Use Salt Setting #3 or #4.  

2

  Iron reduction claims limited to 5 ppm in the state of Wisconsin.

3

  When adding media in the field, check for proper settings. (See Water 

Conditioner Specifications, above.)

4

  Rate of flow must be verified at the end of 1/2-inch I.D. drain line. 

Hague appliance model numbers typically consist of two numerals followed by three letters, such as the 

WaterMax

®

 3BEQ.

3MAQ, 3BAQ, 3BEQ, 2MXQ, 2AMQ, 2APQ are efficiency rated according to NSF/ANSI 44. The stated efficiencies are valid 

only at the specified salt dosage and 8 gpm (30.3 L/min):

An Efficiency-rated water softener is a Demand-initiated regeneration softener that also complies with specific performance 

specifications intended to minimize the amount of regenerant brine and water used in its operation.
Efficiency-rated water softeners shall have a rated salt efficiency of not less than 3,350 grains of total hardness exchange 

per pound of salt (based on NaCI equivalency) (477 grams of total hardness exchange per kilogram of salt), and shall 

not deliver more salt than its listed rating. Efficiency is measured by a laboratory test described in NSF/ANSI 44. The test 

represents the maximum possible efficiency that the system can achieve. Operational efficiency is the actual efficiency 

achieved after the system has been installed. It is typically less than the efficiency due to individual application factors 

including water hardness, water usage, and other contaminates that reduce the softeners’ capacity. 

Refer to the following table as a key for the letters and corresponding media types

The letters BWO added to the end of a filter model number stand for Backwash Only.

Note:

 The iron filter (1AAN) does not have a BWO designation because it uses the regenerant potassium 

 

permanganate.

3MAQ

1

3BAQ

1,2

3BEQ

1,2

2MXQ

1

3MDQ

Max Compensated Hardness–gpg (g/L)

90 (1.5)

90 (1.5)

90 (1.5)

110 (1.9)

90

4

 (1.5)

Iron (ppm)

1

 ferrous-clear water 

Maximum ferrous iron reduction

2

0

0

0

12

5

0

Minimum pH–standard units

7

7

7

7

7

Tannin–ppm

0

0

0

0

0-2

Sulfur–ppm-SulfurStat

0

0

0

0

0

Maximum Chlorine–ppm

0

0

3

0

0

Filtration-nominal rating-microns

20

25

25

20

20

Media Amount Compartment #1

8

–lb (kg)

2.0 (0.9)

2.0 (0.9)

2.0 (0.9)

1.5 (0.7)

1.5 (0.7)

Media Amount Compartment #2

8

–cu. ft. (L)

Empty

Empty

0.4 (11.3)

0.6 (17)

0.3 (8.5)

Media Amount Compartment #3 Fine Mesh Cation Resin–cu. ft. (L)

1.06 (30)

1.06 (30)

1.06 (30)

1.06 (30)

1.06 (30)

Backwash Rate @ min. water pressure  

maximum flow to drain–gpm (L/min)

2.4

4

 (9.1)

3

9

 (11.4)

3

9

 (11.4)

2.4

4

 (9.1)

2.4

4

 (9.1)

Brine Line Flow Control Refill–gpm (L/min)

0.5 (1.9)

0.5 (1.9)

0.5 (1.9)

0.5 (1.9)

0.5 (1.9)

Water Pressure–min–max psi (bar)

20–80

(1.4–5.5)

20–80

(1.4–5.5)

20–80

(1.4–5.5)

20–80

(1.4–5.5)

20–80

(1.4–5.5)

Flow Rate @ 15 psi (1.0 bar) drop-as tested  

–gpm (L/min)11

11.8 (44.7)

13 (49.2)

13 (49.2)

10.8 (40.9)

10.5 (39.7)

Pressure Drop in psi (bar) @ Service Flow Rate  

of 8 gpm (30.3 L/min)

8.0 (0.6)

6.8 (0.5)

6.8 (0.5)

9.8 (0.7)

12 (0.8)

#1 Setting–Salt lb/grains (kg/grams) removed

1.1/5,700

(0.5/369)

1.1/6,000

(0.5/389)

1.1/6,000

(0.5/389)

1.7/9,300

(0.8/603)

NA

#2 Setting—Salt lb/grains (kg/grams) removed

2.7/12,000

(1.2/778)

2.7/12,600

(1.2/816)

2.7/12,600

(1.2/816)

4.2/19,700

(1.9/1277)

NA

#3 Setting—Salt lb/grains (kg/grams) removed

6.2/23,400

(2.8/1,520)

6.2/24,600 

(2.8/1,590)

6.2/24,600 

(2.8/1,590)

9.6/38,300 

(4.4/2,482)

8.5/23,100 

(3.9/1,500)

#4 Setting—Salt lb/grains (kg/grams) removed

9.3/30,600

(4.2/1,980)

9.3/32,100 

(4.2/2,080)

9.3/32,100 

(4.2/2,080)

14.4/50,100 

(6.5/3,250)

10.7/30,300 

(4.9/1,960)

#1 Salt Setting–Total length of reg. Min/gal (L)

25/21

(25/79.5)

25/23 

(25/87)

25/23 

(25/87)

36/26

(36/98)

NA

#2 Salt Setting–Total length of reg. Min/gal (L)

28/22

(28/83)

28/24

(28/91)

28/24

(28/91)

39/28

(39/106)

NA

#3 Salt Setting–Total length of reg. Min/gal (L)

32/24

(32/91)

31/27

(31/102)

31/27

(31/102)

46/31

(46/119)

47/31

(47/117)

#4 Salt Setting–Total length of reg. Min/gal (L)

36/26

(36/100)

36/29

(36/110)

36/29

(36/110)

53/35

(53/132)

64/39

(64/148)

Shipping weight–lb (kg)

135 (61)

152 (69)

152 (69)

168 (76)

152 (69)

Bacteriostatic-KDF® Process Media*

Yes

Yes

Yes

Yes

Yes

1

 Models 3MAQ, 3BAQ, 3BEQ, 2MXQ, 2AMQ and 2APQ are certified by WQA for barium and 

radium reduction as verified and substantiated by test data. All other models are not certified by 

WQA and make no health claims.

2

 Municipally supplied chlorinated water only.

3

 Calcite will add additional hardness to water before softening. 

4

 Any hardness over 10 gpg (0.17 grams/liter) will increase the chance of calcium carbonate 

precipitation. As the

hardness increases so does the chance of this precipitation. Must use citric acid to regenerate 

along with salt. 

5

 Regeneration every 96 hours is required when iron is present in the raw water supply unless 

noted otherwise.

Use Salt Setting #3 or #4. 

6

 Iron reduction claims limited to 5 ppm in the state of Wisconsin.

7

 Must have a minimum of 2 ppm iron and a minimum of 200 ppm TDS. 

8

 When adding media in the field, check for proper settings. (See Water Conditioner 

Specifications, above.) 

9

 Rate of flow must be verified at the end of 1/2-inch I.D. drain line. 

10

 This model has no backwash flow control button or retainer. Must have a minimum of 7 gpm @ 

30 psi (26.5 L/min @ 2.1 bar) available for proper backwash. 

11

 For the purposes of plumbing appliance sizing, only the rated service flow rate and 

corresponding pressure loss may be used. Prolonged operation of a water softener at flow rates 

exceeding the tested service flow rate of 8 gpm (30.3 L/min) may compromise performance.

Summary of Contents for WATERMAX SIGNATURE Series

Page 1: ...Water Conditioning Appliance SIGNATURE SERIES Owner s Manual and Installation Guide Version 1 0...

Page 2: ...ing these substances in the appliance specifications other special treatment of the water supply must be used to remove these substances before they enter this product Otherwise Hague Quality Water In...

Page 3: ...s potassium chloride in place of water conditioner salt A Hague dealer should be contacted before a switch is made to a salt substitute If potassium chloride is used in place of salt the technician mu...

Page 4: ...0 F 4 49 C Drain Drain the appliance to an appropriate drain such as a floor drain or washer drain that will comply with all local and state plumbing codes To prevent back siphoning provide an adequat...

Page 5: ...should make the shortest run to the suitable drain C The drain line may be elevated up to 8 feet 2 4 meters from the discharge on the appliance as long as the water pressure in your system is 40 psi...

Page 6: ...old water faucet to depressurize the lines 3 Close the faucet to eliminate any siphoning action 4 Repair all leaks 5 Turn on the water supply 6 Place the bypass in the Service position to slowly fill...

Page 7: ...jectionable concentrations of ferrous iron or sediment are present Because the blending valve is mixing raw water with softened any ferrous iron or sediment in the raw water will also be blended and r...

Page 8: ...ce Settings History No Total Regenerations Displays the number of regenerations since the last time Service Settings mode was entered Value resets to 0 once the number is viewed 0 Total Gallons Displa...

Page 9: ...m 30 psi available for proper backwash 5 Calcite will add additional hardness to water before softening 6 If iron is present in water supply use salt setting 3 or 4 7 If iron is present in the water s...

Page 10: ...tings Mode 3 is NOT recommended for residential use ST Series 3MAQ1 3BAQ1 2 3BEQ1 2 2MXQ1 3MDQ3 2AMQ1 2APQ1 3 4 2AKQ3 2AJQ3 5 Mode 1 Yes Yes Yes Yes No Yes No No No Regeneration Frequency As Required...

Page 11: ...ttings To maintain peak performance of the appliance inspect and clean the brine tank and air check draw tube assembly annually or when sediment is present in the brine tank Modes 1 and 3 Mode 2 Salt...

Page 12: ...C Close the tap Remove Water From Media Tank A Remove the fill plug from the media tank using a 3 4 inch socket B Insert the siphon hose into the fill port C Siphon the water into the bucket down to...

Page 13: ...L x 3 ___ ppm mg L 0 2 ppm mg L x 3 0 6 ppm mg L Sulfur ___ ppm mg L x 5 ___ ppm mg L 1 0 ppm mg L x 5 5 0 ppm mg L Total compensated ppm ___ ppm mg L 9 1 ppm mg L x Gallons per day for one person 75...

Page 14: ...the container when working with potassium permanganate Use care when removing the cover and pouring it into the feeder B Place the cover on the feeder and secure it with the three stainless steel scr...

Page 15: ...4 3 100241828 Drain End Cap and Container No DLFC See Figure 17 1 4 100241865 O Ring 2 5 100242049 Sleeve 2 6 100241807 Fill Plug 1 7 100241870 O Ring 1 8 100242050 O Ring 2 9 100241175 Bypass Valve...

Page 16: ...t draws the brine solution from the Brine Cabinet The small hole in the Injector Nozzle is the one that creates the injection stream that enters the Throat It is important that this hole is round unda...

Page 17: ...the Sensor Housing The cap is then put in place and the self tapping mount ing screw is installed A slot is provided in the cap for the wire to exit The three wire socket connector must be properly in...

Page 18: ...ft that runs through the main drive axle The Drive Gear is attached at the short end and the Magnet Disc at the other end The Slide Cam is assembled inside of the Piston Slide This Cam Shaft should tu...

Page 19: ...e and then using a twisting action insert the Salt Monitor Probe into the housing Monitor Probe into the housing Caution Caution The 3 8 inch locking clip must be installed to prevent air from being d...

Page 20: ...r No electric power at outlet Check power source Make sure outlet is not controlled by a switch Defective transformer Test with volt meter for 12 VAC at control If less than 10 VAC or greater than 14...

Page 21: ...egenerant potassium permanganate 3MAQ1 3BAQ1 2 3BEQ1 2 2MXQ1 3MDQ Max Compensated Hardness gpg g L 90 1 5 90 1 5 90 1 5 110 1 9 904 1 5 Iron ppm 1 ferrous clear water Maximum ferrous iron reduction2 0...

Page 22: ...minimum of 200 ppm TDS 8 When adding media in the field check for proper settings See Water Conditioner Specifications above 9 Rate of flow must be verified at the end of 1 2 inch I D drain line 10 T...

Page 23: ...2022 A O Smith All Rights Reserved 100359102 DOCUMENT NUMBER RevA0123 A O Smith Water Treatment North America Inc...

Reviews: