Service Settings, Cont.

Service Settings — History

History is an optional set of menus that acts as a clipboard for storing the history of water chemistry, total regenerations, 

amount of water to pass through the unit, unit model number, and other settings. The history can be used for diagnosis 

purposes or just for reference. History settings DO NOT affect operation.

When you select “Yes” in the history screen, the following screens will be available. Take notice of the “H-” prefix to signify 

that you are viewing the history.

Service Settings – History (if set to Yes)

Title

Function

Factory Setting

Serial Number

(For Reference Only)

AR0726

H-Software V. #

Software version number (For Reference Only)

V1.1

H-Date

Enter Installation Date Format MMDDYY

0

H-Number of People

Enter number of people in the household (1 to 50)

4

H-Hardness grains

Enter hardness test results (0 to 199 ppm (mg/L))

1

H-Iron ppm

Enter iron test results (0 to 99 ppm (mg/L))

0

H-Manganese ppm

Enter manganese test results (0 to 99 ppm (mg/L))

0

H-Chlorine ppm

Enter chlorine test results (0 to 99 ppm (mg/L))

1

H-Sulfur ppm

Enter sulfur test results (0 to 99 ppm (mg/L))

1

H-pH ppm

Enter pH test results (0 to 99.9)

00.0

H-Iron Bacteria

Is iron bacteria present (Yes or No)

No 

H-Total Regenerations

Number of regenerations completed. Value does not reset  

(For Reference Only)

0

H-Total Gallons

Number of gallons that have passed through the unit. Value does not 

reset (For Reference Only)

0

H-Hours Over Max Temp.

Hours over 120 degrees Fahrenheit

0

H-Model Number

Enter model number

3MAQ

H-Save History

Choose to save history (Yes or No)

Yes

Service Settings

To program Service Settings on the controller, tap on the screen to bring up the “Main Menu.” 

Tap the Service Settings button  

  . The values that can be set are listed below. (Metric values are in parentheses.)

Note:

 The Service Settings must be set before the Customer Settings. 

Title

Function

Factory Setting

Password

Enter the password

1397

Language 

Select the desired language (English, Français, Español, Deutsch, Italiano)

English

Units

Select units of measure (Metric or English)

Eng

History?

Option to show history (Yes or No) (see Service Settings—History) 

No

Total Regenerations

Displays the number of regenerations since the last time Service Settings 

mode was entered. Value resets to 0 once the number is viewed

0

Total Gallons

Displays the number of gallons that have passed through the unit since 

the last time Service Settings mode was entered. Value resets to 0 once 

the number is viewed 

0

Mode (1–3)

Enter operating mode (1 to 3) (see Operating Modes)

2

Hardness Grains

Enter hardness test results (1 to 199 grains) or (0000 to 3999 mg/L)

40

Iron ppm*

Enter iron test results (0 to 99 ppm (mg/L))

0

Manganese ppm

Enter manganese test results (0 to 99 ppm (mg/L))

0

Salt

Select regenerant (Sodium or Potassium)

Sodium

Compensated Hardness 

Grains

Automatically calculated

40

Capacity Grains

The desired capacity number (52 to 99999 grains) or (788 to 6999 gm)

24480

Backwash 1 Minutes

First backwash cycle duration (0 to 999.9)

001.0

Brine/Rinse Minutes

Brine and rinse cycle duration (0 to 999.9)

030.0

Backwash 2 Minutes

Second backwash cycle duration (0 to 999.9)

005.0

72–96 hour Regeneration

Force regeneration setting every 72 to 96 hours unless a demand based 

regeneration occurs within time interval (Yes or No)

Yes*

Distiller/RO

Yes, if distiller or RO in use

Yes

Turbine Test

Used for advanced diagnosis (Yes or No)

No

Salt Monitor

Optional salt monitor in use (Yes or No)

No 

Salt lb

Amount of salt for each regeneration

006.2

Low Temp Alarm

Optional, detects low ambient temperature (Yes or No)

Yes

Water Usage Alarm

Optional, detects prolonged non-stop water flow (Yes or No)

Yes

Turbine Disconnect Alarm

Optional, detects disconnected sensor wire (Yes or No)

Yes

Regenerate Tonight

Set to regenerate tonight (Yes or No)

No 

Dealer Name

Enter the dealership/business name

Dealer name

Dealer Number

Enter the dealership/business phone number

800-123-4567

*Required if iron is present

Button

Function

Ok

Sets the information and moves to the next screen

Back

Navigates to the previous screen

Clr

Resets all values to 0 and/or to the default value

Esc

Escapes to the main menu

day

Advances to the next day, when applicable

AP

Toggles between AM and PM, when applicable

Service Settings — Button Functions

Please reference the chart to the right in order to properly 

navigate the service settings area. These are the button  

options that will be shown on screen throughout the process.

Summary of Contents for WATERMAX SIGNATURE Series

Page 1: ...Water Conditioning Appliance SIGNATURE SERIES Owner s Manual and Installation Guide Version 1 0...

Page 2: ...ing these substances in the appliance specifications other special treatment of the water supply must be used to remove these substances before they enter this product Otherwise Hague Quality Water In...

Page 3: ...s potassium chloride in place of water conditioner salt A Hague dealer should be contacted before a switch is made to a salt substitute If potassium chloride is used in place of salt the technician mu...

Page 4: ...0 F 4 49 C Drain Drain the appliance to an appropriate drain such as a floor drain or washer drain that will comply with all local and state plumbing codes To prevent back siphoning provide an adequat...

Page 5: ...should make the shortest run to the suitable drain C The drain line may be elevated up to 8 feet 2 4 meters from the discharge on the appliance as long as the water pressure in your system is 40 psi...

Page 6: ...old water faucet to depressurize the lines 3 Close the faucet to eliminate any siphoning action 4 Repair all leaks 5 Turn on the water supply 6 Place the bypass in the Service position to slowly fill...

Page 7: ...jectionable concentrations of ferrous iron or sediment are present Because the blending valve is mixing raw water with softened any ferrous iron or sediment in the raw water will also be blended and r...

Page 8: ...ce Settings History No Total Regenerations Displays the number of regenerations since the last time Service Settings mode was entered Value resets to 0 once the number is viewed 0 Total Gallons Displa...

Page 9: ...m 30 psi available for proper backwash 5 Calcite will add additional hardness to water before softening 6 If iron is present in water supply use salt setting 3 or 4 7 If iron is present in the water s...

Page 10: ...tings Mode 3 is NOT recommended for residential use ST Series 3MAQ1 3BAQ1 2 3BEQ1 2 2MXQ1 3MDQ3 2AMQ1 2APQ1 3 4 2AKQ3 2AJQ3 5 Mode 1 Yes Yes Yes Yes No Yes No No No Regeneration Frequency As Required...

Page 11: ...ttings To maintain peak performance of the appliance inspect and clean the brine tank and air check draw tube assembly annually or when sediment is present in the brine tank Modes 1 and 3 Mode 2 Salt...

Page 12: ...C Close the tap Remove Water From Media Tank A Remove the fill plug from the media tank using a 3 4 inch socket B Insert the siphon hose into the fill port C Siphon the water into the bucket down to...

Page 13: ...L x 3 ___ ppm mg L 0 2 ppm mg L x 3 0 6 ppm mg L Sulfur ___ ppm mg L x 5 ___ ppm mg L 1 0 ppm mg L x 5 5 0 ppm mg L Total compensated ppm ___ ppm mg L 9 1 ppm mg L x Gallons per day for one person 75...

Page 14: ...the container when working with potassium permanganate Use care when removing the cover and pouring it into the feeder B Place the cover on the feeder and secure it with the three stainless steel scr...

Page 15: ...4 3 100241828 Drain End Cap and Container No DLFC See Figure 17 1 4 100241865 O Ring 2 5 100242049 Sleeve 2 6 100241807 Fill Plug 1 7 100241870 O Ring 1 8 100242050 O Ring 2 9 100241175 Bypass Valve...

Page 16: ...t draws the brine solution from the Brine Cabinet The small hole in the Injector Nozzle is the one that creates the injection stream that enters the Throat It is important that this hole is round unda...

Page 17: ...the Sensor Housing The cap is then put in place and the self tapping mount ing screw is installed A slot is provided in the cap for the wire to exit The three wire socket connector must be properly in...

Page 18: ...ft that runs through the main drive axle The Drive Gear is attached at the short end and the Magnet Disc at the other end The Slide Cam is assembled inside of the Piston Slide This Cam Shaft should tu...

Page 19: ...e and then using a twisting action insert the Salt Monitor Probe into the housing Monitor Probe into the housing Caution Caution The 3 8 inch locking clip must be installed to prevent air from being d...

Page 20: ...r No electric power at outlet Check power source Make sure outlet is not controlled by a switch Defective transformer Test with volt meter for 12 VAC at control If less than 10 VAC or greater than 14...

Page 21: ...egenerant potassium permanganate 3MAQ1 3BAQ1 2 3BEQ1 2 2MXQ1 3MDQ Max Compensated Hardness gpg g L 90 1 5 90 1 5 90 1 5 110 1 9 904 1 5 Iron ppm 1 ferrous clear water Maximum ferrous iron reduction2 0...

Page 22: ...minimum of 200 ppm TDS 8 When adding media in the field check for proper settings See Water Conditioner Specifications above 9 Rate of flow must be verified at the end of 1 2 inch I D drain line 10 T...

Page 23: ...2022 A O Smith All Rights Reserved 100359102 DOCUMENT NUMBER RevA0123 A O Smith Water Treatment North America Inc...

Reviews: