Service Settings, Cont.
Service Settings — History
History is an optional set of menus that acts as a clipboard for storing the history of water chemistry, total regenerations,
amount of water to pass through the unit, unit model number, and other settings. The history can be used for diagnosis
purposes or just for reference. History settings DO NOT affect operation.
When you select “Yes” in the history screen, the following screens will be available. Take notice of the “H-” prefix to signify
that you are viewing the history.
Service Settings – History (if set to Yes)
Title
Function
Factory Setting
Serial Number
(For Reference Only)
AR0726
H-Software V. #
Software version number (For Reference Only)
V1.1
H-Date
Enter Installation Date Format MMDDYY
0
H-Number of People
Enter number of people in the household (1 to 50)
4
H-Hardness grains
Enter hardness test results (0 to 199 ppm (mg/L))
1
H-Iron ppm
Enter iron test results (0 to 99 ppm (mg/L))
0
H-Manganese ppm
Enter manganese test results (0 to 99 ppm (mg/L))
0
H-Chlorine ppm
Enter chlorine test results (0 to 99 ppm (mg/L))
1
H-Sulfur ppm
Enter sulfur test results (0 to 99 ppm (mg/L))
1
H-pH ppm
Enter pH test results (0 to 99.9)
00.0
H-Iron Bacteria
Is iron bacteria present (Yes or No)
No
H-Total Regenerations
Number of regenerations completed. Value does not reset
(For Reference Only)
0
H-Total Gallons
Number of gallons that have passed through the unit. Value does not
reset (For Reference Only)
0
H-Hours Over Max Temp.
Hours over 120 degrees Fahrenheit
0
H-Model Number
Enter model number
3MAQ
H-Save History
Choose to save history (Yes or No)
Yes
Service Settings
To program Service Settings on the controller, tap on the screen to bring up the “Main Menu.”
Tap the Service Settings button
. The values that can be set are listed below. (Metric values are in parentheses.)
Note:
The Service Settings must be set before the Customer Settings.
Title
Function
Factory Setting
Password
Enter the password
1397
Language
Select the desired language (English, Français, Español, Deutsch, Italiano)
English
Units
Select units of measure (Metric or English)
Eng
History?
Option to show history (Yes or No) (see Service Settings—History)
No
Total Regenerations
Displays the number of regenerations since the last time Service Settings
mode was entered. Value resets to 0 once the number is viewed
0
Total Gallons
Displays the number of gallons that have passed through the unit since
the last time Service Settings mode was entered. Value resets to 0 once
the number is viewed
0
Mode (1–3)
Enter operating mode (1 to 3) (see Operating Modes)
2
Hardness Grains
Enter hardness test results (1 to 199 grains) or (0000 to 3999 mg/L)
40
Iron ppm*
Enter iron test results (0 to 99 ppm (mg/L))
0
Manganese ppm
Enter manganese test results (0 to 99 ppm (mg/L))
0
Salt
Select regenerant (Sodium or Potassium)
Sodium
Compensated Hardness
Grains
Automatically calculated
40
Capacity Grains
The desired capacity number (52 to 99999 grains) or (788 to 6999 gm)
24480
Backwash 1 Minutes
First backwash cycle duration (0 to 999.9)
001.0
Brine/Rinse Minutes
Brine and rinse cycle duration (0 to 999.9)
030.0
Backwash 2 Minutes
Second backwash cycle duration (0 to 999.9)
005.0
72–96 hour Regeneration
Force regeneration setting every 72 to 96 hours unless a demand based
regeneration occurs within time interval (Yes or No)
Yes*
Distiller/RO
Yes, if distiller or RO in use
Yes
Turbine Test
Used for advanced diagnosis (Yes or No)
No
Salt Monitor
Optional salt monitor in use (Yes or No)
No
Salt lb
Amount of salt for each regeneration
006.2
Low Temp Alarm
Optional, detects low ambient temperature (Yes or No)
Yes
Water Usage Alarm
Optional, detects prolonged non-stop water flow (Yes or No)
Yes
Turbine Disconnect Alarm
Optional, detects disconnected sensor wire (Yes or No)
Yes
Regenerate Tonight
Set to regenerate tonight (Yes or No)
No
Dealer Name
Enter the dealership/business name
Dealer name
Dealer Number
Enter the dealership/business phone number
800-123-4567
*Required if iron is present
Button
Function
Ok
Sets the information and moves to the next screen
Back
Navigates to the previous screen
Clr
Resets all values to 0 and/or to the default value
Esc
Escapes to the main menu
day
Advances to the next day, when applicable
AP
Toggles between AM and PM, when applicable
Service Settings — Button Functions
Please reference the chart to the right in order to properly
navigate the service settings area. These are the button
options that will be shown on screen throughout the process.