background image

22

23

2AJQ Replenishment Procedure

2AJQ Replenishment Procedure,Cont.

The neutralizing media that adjusts the pH level of the water must be refilled periodically. Typically, this media is calcite and 

is available from Hague. To refill the neutralizing media, measure the appliance’s media bed depth upon installation (factory 

freeboard). Use this measurement to determine the amount of media to add to maintain optimum performance of the 2AJQ.

Tools and Materials Needed

The following tools and materials are needed to replace the neutralizing media:

 Analog scale (do not use digital)  

 5-gallon bucket with handle

 1/2-inch siphon hose   

 

 12-inch wooden ruler or dowel rod

 Steel tape measure   

 

 Replacement media (P/N 100242302)

 Funnel with 1-inch fill tube 

 

 3/4-inch socket

Replenishment Procedure

The replenishment procedure is as follows:

The following pages provide information about the Hague Iron Filter and Potassium Permanganate Feeder.

Step 1

Step 4

Step 2

Step 5

Step 3

Step 6

Step 7

Turn Off the Water

A.

 

Turn off the water to the appliance.

B.

 

Open a tap to depressurize the appliance.

C.

 

Close the tap.

Remove Water From Media Tank

A.

 

Remove the fill plug from the media tank using a 3/4-inch 

socket.

B.

 

Insert the siphon hose into the fill port.

C.

 

Siphon the water into the bucket down to the media level in 

the tank.

Calculate Amount of Media to Add

A.

 

Measure the freeboard distance from the top of the fill plug to 

the media. See Figure 5.  

Note

: The recommended freeboard distance is 4-3/4-inch (12 cm).

B.

 

Add five pounds (2.3 kg) of media per inch (2.5 cm) below 

4-3/4-inches (12 cm).

Add Replenishment Media

A.

 

Weigh the replenishment media.

B.

 

Place the funnel into the fill port.

C.

 

Pour the media into the funnel to fill the tank with the measured amount of media.

Refill Tank With Water

A.

 

Open the main water valve.

B.

 

Slowly fill the tank with water up to the bottom of the fill port.

C.

 

Turn off the water.

Replace Fill Plug

A.

 

Make sure the threads of the fill port are clean.

B.

 

Replace the fill plug. 

 

Caution:

 Do not overtighten the fill plug.

Check for Leaks

A.

 

Turn on the water to re-pressurize the appliance.

B.

 

Check for leaks.

C.

 

Fix any leaks.

Figure 5: Max Freeboard Amount

Example:

 

Measured Freeboard   

6-3/4 inches (17.1cm)

Minus factory Freeboard             -4-3/4 inches (12.1cm)
Adjusted Freeboard 

 

      2 inches (5.0cm)

Replenishment equals 

5lb (2.3 kg) media x 2 inches (2.5 cm) (adjusted freeboard) = 10lb (4.5kg) media.

Summary of Contents for WATERMAX SIGNATURE Series

Page 1: ...Water Conditioning Appliance SIGNATURE SERIES Owner s Manual and Installation Guide Version 1 0...

Page 2: ...ing these substances in the appliance specifications other special treatment of the water supply must be used to remove these substances before they enter this product Otherwise Hague Quality Water In...

Page 3: ...s potassium chloride in place of water conditioner salt A Hague dealer should be contacted before a switch is made to a salt substitute If potassium chloride is used in place of salt the technician mu...

Page 4: ...0 F 4 49 C Drain Drain the appliance to an appropriate drain such as a floor drain or washer drain that will comply with all local and state plumbing codes To prevent back siphoning provide an adequat...

Page 5: ...should make the shortest run to the suitable drain C The drain line may be elevated up to 8 feet 2 4 meters from the discharge on the appliance as long as the water pressure in your system is 40 psi...

Page 6: ...old water faucet to depressurize the lines 3 Close the faucet to eliminate any siphoning action 4 Repair all leaks 5 Turn on the water supply 6 Place the bypass in the Service position to slowly fill...

Page 7: ...jectionable concentrations of ferrous iron or sediment are present Because the blending valve is mixing raw water with softened any ferrous iron or sediment in the raw water will also be blended and r...

Page 8: ...ce Settings History No Total Regenerations Displays the number of regenerations since the last time Service Settings mode was entered Value resets to 0 once the number is viewed 0 Total Gallons Displa...

Page 9: ...m 30 psi available for proper backwash 5 Calcite will add additional hardness to water before softening 6 If iron is present in water supply use salt setting 3 or 4 7 If iron is present in the water s...

Page 10: ...tings Mode 3 is NOT recommended for residential use ST Series 3MAQ1 3BAQ1 2 3BEQ1 2 2MXQ1 3MDQ3 2AMQ1 2APQ1 3 4 2AKQ3 2AJQ3 5 Mode 1 Yes Yes Yes Yes No Yes No No No Regeneration Frequency As Required...

Page 11: ...ttings To maintain peak performance of the appliance inspect and clean the brine tank and air check draw tube assembly annually or when sediment is present in the brine tank Modes 1 and 3 Mode 2 Salt...

Page 12: ...C Close the tap Remove Water From Media Tank A Remove the fill plug from the media tank using a 3 4 inch socket B Insert the siphon hose into the fill port C Siphon the water into the bucket down to...

Page 13: ...L x 3 ___ ppm mg L 0 2 ppm mg L x 3 0 6 ppm mg L Sulfur ___ ppm mg L x 5 ___ ppm mg L 1 0 ppm mg L x 5 5 0 ppm mg L Total compensated ppm ___ ppm mg L 9 1 ppm mg L x Gallons per day for one person 75...

Page 14: ...the container when working with potassium permanganate Use care when removing the cover and pouring it into the feeder B Place the cover on the feeder and secure it with the three stainless steel scr...

Page 15: ...4 3 100241828 Drain End Cap and Container No DLFC See Figure 17 1 4 100241865 O Ring 2 5 100242049 Sleeve 2 6 100241807 Fill Plug 1 7 100241870 O Ring 1 8 100242050 O Ring 2 9 100241175 Bypass Valve...

Page 16: ...t draws the brine solution from the Brine Cabinet The small hole in the Injector Nozzle is the one that creates the injection stream that enters the Throat It is important that this hole is round unda...

Page 17: ...the Sensor Housing The cap is then put in place and the self tapping mount ing screw is installed A slot is provided in the cap for the wire to exit The three wire socket connector must be properly in...

Page 18: ...ft that runs through the main drive axle The Drive Gear is attached at the short end and the Magnet Disc at the other end The Slide Cam is assembled inside of the Piston Slide This Cam Shaft should tu...

Page 19: ...e and then using a twisting action insert the Salt Monitor Probe into the housing Monitor Probe into the housing Caution Caution The 3 8 inch locking clip must be installed to prevent air from being d...

Page 20: ...r No electric power at outlet Check power source Make sure outlet is not controlled by a switch Defective transformer Test with volt meter for 12 VAC at control If less than 10 VAC or greater than 14...

Page 21: ...egenerant potassium permanganate 3MAQ1 3BAQ1 2 3BEQ1 2 2MXQ1 3MDQ Max Compensated Hardness gpg g L 90 1 5 90 1 5 90 1 5 110 1 9 904 1 5 Iron ppm 1 ferrous clear water Maximum ferrous iron reduction2 0...

Page 22: ...minimum of 200 ppm TDS 8 When adding media in the field check for proper settings See Water Conditioner Specifications above 9 Rate of flow must be verified at the end of 1 2 inch I D drain line 10 T...

Page 23: ...2022 A O Smith All Rights Reserved 100359102 DOCUMENT NUMBER RevA0123 A O Smith Water Treatment North America Inc...

Reviews: