OR-05/18/15
Maximizer
®
97 Owner’s Manual
35
Quality Water International
®
Maximizer
®
Model 97
97MM
Max Compensated Hardness - gpg (g/L)
90 (1540)
Maximum ferrous iron reduction
1
- ppm
10
Minimum pH - standard units
7
Filtration - nominal rating - microns
20
Media Amount - cu. ft. (L) and Type
1.0 (28)
Fine Mesh Cation Resin
Backwash Rate @ min. water pressure maximum flow to drain - gpm (L/min)
2
2.4 (9.1)
Backwash Rate @ min. water pressure maximum flow to drain
(97MMB1 or 97MMP1 only) - gpm (L/min)
2
3.0 (11.4)
Water Pressure - min–max psi (bar)
20–120 (1.4/8.3)
Flow Rate @ 15 psi (1.0 bar) drop-as tested by Hague - gpm (L/min)
3
10.7 (40.5)
Pressure Drop in psi (bar) @ Service Flow Rate of 8 gpm (30 L/min)
9.9 (0.7)
#1 Setting - Salt lb/grains (kg/grams) removed
1/5,400 (0.5/350)
#2 Setting - Salt lb/grains (kg/grams) removed
3/13,700 (1.4/888)
#3 Setting - Salt lb/grains (kg/grams) removed
6/23,700 (2.7/1,540)
#4 Setting - Salt lb/grains (kg/grams) removed
9/30,800 (4.1/2,000)
#1 Salt Setting - Total length of regeneration - min/gal (L)
25/20 (76)
#2 Salt Setting - Total length of regeneration - min/gal (L)
27.5/21 (79)
#3 Salt Setting - Total length of regeneration - min/gal (L)
31.5/23 (87)
#4 Salt Setting - Total length of regeneration - min/gal (L)
35.5/25 (95)
Minimum / Maximum water and ambient temperature - °F (°C)
40/120 (4/49)
Salt storage - lb (kg)
170 (77)
Height - in. (cm)
30 (76)
Footprint - in. (cm)
15 x 19 (38 x 48)
Electrical rating
115 V, 60 Cycle
Plumbing connections
1-1/4-inch male (MNPT)
For All Models:
Use clean white pellet, cube-style, or solar salt.
Drain Line (Minimum I.D.) 1/2-inch
Brine & Rinse total–0.75 gpm (2.8 L/min)
Brine Draw–0.25 gpm (0.9 L/min)
Rinse–0.5 gpm (1.9 L/min)
1
Iron reduction to 0.3 ppm or less. Iron reduction claims limited to 5 ppm in the
state of Wisconsin.
2
Rate of flow must be verified at the end of the drain line.
3
For the purposes of plumbing appliance sizing, only the rated service flow rate
and corresponding pressure loss may be used. Prolonged operation of a water
softener at flow rates exceeding the tested service flow rate of 8 gpm (30 L/min)
may compromise performance.
Water Conditioner Specifications
Specifications