Mode 1 - Timer Mode - Frequency
Mode 1 - Timer Mode - Days of Week
Mode 2 - Demand Delayed Mode
Mode 3 - Demand Immediate Mode
72 - 96 Hour Regeneration
Smart Touch Operating Modes
When the appliance is in Mode 1 -
Frequency
, it will regenerate based on the frequency that is set.
For example every one day or up to every 20 days. The days between regenerations can be set in the “Service Settings”.
When Frequency is selected, the next
screen will allow you to chose how
many days between regenerations.
When Days of Week is selected, the
regeneration days can be selected in
the “Customer Settings”.
In “Customer Settings”, check the
days in which you would like the unit
to regenerate. “OK” to continue.
Enter the number of days (1-20)
between regenerations.
When the appliance is in Mode 1 -
Days of Week
, it will regenerate on a specific day(s) of the week.
When the appliance is in the Patented Savematic Demand Delayed mode, it will regenerate based on the actual water
usage and the total capacity of the appliance. The time that the regeneration takes place can be set, for example 2:00
AM. Should the total capacity be depleted before the set regeneration time, a forced regeneration will occur.
When the appliance is in the Demand Immediate mode, it will regenerate based on water usage alone. Regeneration will
occur when the capacity limit is reached. The time of regeneration cannot be set.
If this value is set to Yes, the appliance will be forced to regenerate every 96 hours unless a regeneration based on water
usage occurs within the time interval. The value should always be set to Yes if iron is present in the water.
The controller has a Timer mode (Mode 1 Frequency and Mode 1 Days of the Week), a Demand Delayed mode (Mode
2), and a Demand Immediate mode (Mode 3). These modes are equipped with Capacity Guard
®
, which ensures that a
supply of conditioned water will be available even with excessive water usage.