BALCONY CLAMP
The balcony clamp allows the ladder structure of the hoist to be positioned and locked perpendicular to the
building façade on a balcony or a concrete floor.
Adjusting the balcony clamp:
-
Unscrew the clamping handle (1).
-
Remove the clip pin to release the sliding spur (2).
-
Adjust the position of the sliding spur on the rod so that the space between the base of the clamping
handle and the fixed spur is slightly greater than the thickness of the balcony or the concrete floor
where the balcony clamp (3) will be installed.
-
Replace the clip pin to lock the sliding spur.
Installation of the balcony clamp:
-
Bring the balcony clamp to the level of the balcony or concrete floor (1).
-
The vertical tube must be in contact with the edge of the balcony or the concrete floor.
-
Secure the balcony clamp by turning the clamping handle with a properly shaped tube (2). The
minimum tightening torque to be applied to the clamping handle is 50Nm.
-
Proceed in the same way to install the other balcony clamps on each floor ensuring that all the
following balcony clamps on the upper floors are perfectly aligned vertically.
1
2
3
1
2
Summary of Contents for 312175001
Page 14: ...14 SAFETY MARKINGS ON THE MACHINE WINCH BASE LADDER HEADBOARD ACCESSORIES...
Page 18: ...18 ASSEMBLY EXAMPLES...
Page 40: ...40 OVERLOAD OF THE DOUBLE TIPPING SKIP MAX PAYLOAD 150kg...
Page 51: ...51 EXAMPLES OF INCLINED INSTALLATIONS OF THE HOIST ON THE FA ADE OF A BUILDING...
Page 60: ...60 EXAMPLES OF VERTICAL INSTALLATIONS OF THE HOIST ON THE FA ADE OF A BUILDING...
Page 67: ...67 1 1 2 2 2 1 4 4 3 3...
Page 70: ...70...
Page 75: ...75...
Page 86: ...86 ELECTRICAL DIAGRAM OF THE ABM VF 200 250 WINCHES for MAXIAL EXCELLIUM and EXPERT...
Page 87: ...87 DETAILS OF ELECTRICAL CONNECTIONS TO THE FREQUENCY CONVERTER...