28
INSTALLATION OF THE GUIDE HOOKS FOR THE UPPER LIMIT
ELECTRICAL CABLE
The guide hooks are used to guide the electrical cable of the upper limit switch along the ladder mat of the
hoist to prevent the cable from hanging freely in the void and being damaged, crushed or cut.
The shape of the guide hooks allows them to be easily and quickly attached to the rings of the quick bolts
at the connections between ladders and at the knee joints.
A set of 3 guide hooks is supplied with each hoist. As a rule, a set of 3 hooks is sufficient for base heights
between 10 and 11m. When the total height of the lift exceeds 11m and depending on the inclination, as
many hooks as necessary must be added to ensure optimal guidance of the upper limit switch cable.
These hooks are available in sets of 3 pieces under the article code 312703001.
Installation of hooks:
-
Bring the guide hook close to a quick bolt ring at the ladder connections or knee joints.
-
Engage the spiral end of the hook in the ring of the quick bolt (1)
-
Then turn the hook 180° so that the spiral is screwed around the ring (2)
-
Release the hook, it is now in place and ready to receive the electric cable to be guided (3)
-
1
1
2
3
Summary of Contents for 312175001
Page 14: ...14 SAFETY MARKINGS ON THE MACHINE WINCH BASE LADDER HEADBOARD ACCESSORIES...
Page 18: ...18 ASSEMBLY EXAMPLES...
Page 40: ...40 OVERLOAD OF THE DOUBLE TIPPING SKIP MAX PAYLOAD 150kg...
Page 51: ...51 EXAMPLES OF INCLINED INSTALLATIONS OF THE HOIST ON THE FA ADE OF A BUILDING...
Page 60: ...60 EXAMPLES OF VERTICAL INSTALLATIONS OF THE HOIST ON THE FA ADE OF A BUILDING...
Page 67: ...67 1 1 2 2 2 1 4 4 3 3...
Page 70: ...70...
Page 75: ...75...
Page 86: ...86 ELECTRICAL DIAGRAM OF THE ABM VF 200 250 WINCHES for MAXIAL EXCELLIUM and EXPERT...
Page 87: ...87 DETAILS OF ELECTRICAL CONNECTIONS TO THE FREQUENCY CONVERTER...