13
-
Read the instructions on the sheets and labels attached to the hoist.
-
Ensure that the building or structure against which the machine is to be installed is capable of
withstanding the reaction forces due to the passing of the loaded mobile crew.
-
Ensure that the loading and unloading areas and the area around the installation are clean.
-
Mark out the danger zone with a physical system. All workplaces must be protected by guardrails in
accordance with current regulations, consisting of two horizontal elements. One should be at a
height of between 1 and 1.2m, the other at a height of about 0.5m. These elements should be
marked in an eye-catching colour (e.g. red and white). The marked out space must protect an area
of a width corresponding to the largest load envisaged, for a distance of at least 1.40m.
-
To ensure the protection of the people who install the equipment as well as the users.
-
In all cases, the person or persons installing the machine at a height must wear a safety harness
with a fall arrest system, anchored to a suitable part of the building.
The structure and equipment of the hoist must not be used as an anchoring point for the
safety harness.
-
It is strictly forbidden to transport people.
-
It is strictly forbidden to access the transport devices.
-
Never overload the transport device.
-
Mark out and protect the risk area in a suitable manner to prevent the circulation of
personnel underneath the load and highlight the danger of a falling load.
Before each use of the hoist, the operator must make sure that no one is in the defined area and
under the load.
-
Observe all instructions and warnings.
-
Before connecting the winch, check that the power supply complies with the manufacturer's
instructions and ensure that:
o
The supply voltage is 220V50Hz single phase,
o
The power supply line can support a current of 16A,
o
The power supply line is initially protected by a high sensitivity differential device
30mA for the protection of persons and a circuit breaker at maximum 16A for the
protection of the winch against overloads or short circuits,
o
When using an electric extension cable, make sure that the cable conductors have
a cross-section of 2.5mm2 or over each for a length of less than 25m, and
4mm2 each for a length of more than 25m,
o
The device does not work in ATEX zones or explosive atmospheres (presence of flammable
gas or dust etc.).
-
Never operate the winch while it is connected to a power source.
-
If the winch does not start or does not pull the rated load or shows other anomalies, immediately
stop using it, disconnect it and contact the after-sales service.
-
It is not necessary to systematically use the upper limit switch. The winch stops as soon as you
release the up or down buttons.
-
For proper operation of the winch, respect the intermittent service of 25% (corresponds to
approximately 17 cycles per hour maximum for the Maxial Premium and 20 cycles per hour for the
Maxial Excellium and Expert).
-
Observe the operating temperature range of -5 to 40°C
-
This manual concerns all versions of Maxial Premium, Excellium and Expert.
-
The basic compositions are equipped with a roofer platform or universal platform. Nevertheless, it is
recommended to use the most suitable accessory for the material to be transported in order to work
in safety (see other accessories available on page 9 as well as in the commercial documentation
and on our website
Summary of Contents for 312175001
Page 14: ...14 SAFETY MARKINGS ON THE MACHINE WINCH BASE LADDER HEADBOARD ACCESSORIES...
Page 18: ...18 ASSEMBLY EXAMPLES...
Page 40: ...40 OVERLOAD OF THE DOUBLE TIPPING SKIP MAX PAYLOAD 150kg...
Page 51: ...51 EXAMPLES OF INCLINED INSTALLATIONS OF THE HOIST ON THE FA ADE OF A BUILDING...
Page 60: ...60 EXAMPLES OF VERTICAL INSTALLATIONS OF THE HOIST ON THE FA ADE OF A BUILDING...
Page 67: ...67 1 1 2 2 2 1 4 4 3 3...
Page 70: ...70...
Page 75: ...75...
Page 86: ...86 ELECTRICAL DIAGRAM OF THE ABM VF 200 250 WINCHES for MAXIAL EXCELLIUM and EXPERT...
Page 87: ...87 DETAILS OF ELECTRICAL CONNECTIONS TO THE FREQUENCY CONVERTER...