HAEHNE
Elektronische Messgeräte GmbH · Heinrich-Hertz-Str. 29 · D-40699 Erkrath Germany · Telefon 0211/9 25 91-0 · Fax 0211/9 25 91-20
http://www.haehne.de
Email: [email protected]
HAEHNE
Elektronische Messgeräte GmbH · Heinrich-Hertz-Str. 29 · D-40699 Erkrath Germany · Telefon 0211/9 25 91-0 · Fax 0211/9 25 91-20
http://www.haehne.de
Email: [email protected]
DCX
26 Block 4
6.3.2. Anybus Inputs (Block 1)
Configuration of 8 Anybus Analog Inputs
Within the individual blocks of the DCX more filter functions are selectable, in addition to the input filters.
The combination of these functions results in a total filter effect.
Block
Channel 1...8
Number
Range:
0; 1
0:
Channel x of Anybus inputs OFF (Standard)
At the output of channel x of this block "0" is always present
1:
Channel x of Anybus inputs on
4 I x 0 0
ON / OFF
Level
Range:
1 ....9999
Designation in ms
Standard: 1
Value of t
he moving average
1: Filter function not in operation
From the value 52 onwards an additional peak suppression func
-
tion is activated. However, local peaks do not enter into the aver
-
age calculation.
3 I x I I
Filter time
(Block 1)
Anybus analog input [1..8]
Anybus CompactCom Modul x
31x11
Filter
time
Output
Example 1
Example 3
(Standard)
Example 2
Source
Examplel 4
31x21
Scaling at
0-signal
(0x0)
31x22
Scaling at
nominal signal
(0x5000 bzw. 20480)
Selection number: 1x
41x00