10
The Tx and Rx connectors are correctly connected.
The fiber ends are clean.
Checking the Installation
After installation, make sure that:
The correct power supply is used.
The ground wire is properly connected.
Both the console cable and power cord are correctly connected.
All interface cables are routed indoors. If there are outdoor cables, check that
lightning arresters for the AC power strip and network interfaces have been
correctly connected. For how to connect the lightning arresters for the AC power
supply and network interfaces, see Appendixes A and B in the
H3C WX5004
Installation Guide
.
Initial startup
Setting terminal parameters
1.
Start the PC and run the terminal emulation program, such as the Terminal of
Windows 3.1 or the HyperTerminal of Windows 95/98/NT/2000/XP.
2.
Select
Start
>
Program
>
Accessories
>
Communications
>
HyperTerminal
. On the
Connection Description
interface, type the name of the new connection and click
OK
.
3.
The system displays the
Connect To
interface. From the
Connect using
drop-down
list, select the serial interface to be used. (Be sure to select the serial interface to
which the console cable is actually connected.) Click
OK
.
4.
The system displays the port settings. Set
Bits per second
to
9600
,
Data bits
to
8
,
Parity
to
None
,
Stop bits
to
1
, and
Flow control
to
None
. To use the default settings,
click
Restore Defaults
. Click
OK
.
5.
The system displays the HyperTerminal interface. Select
File
>
Properties
>
Settings
in
the HyperTerminal to enter the properties setting window. Select
VT100
as the
terminal emulation, and click
OK
.
Powering on the access controller
Before powering on the access controller, verify that: