6-33
To install a 4SFF drive backplane:
1.
Power off the server. For more information, see "
2.
Remove the security bezel, if any. For more information, see "
3.
Remove the compute module. For more information, see "
."
4.
Remove the compute module access panel. For more information, see "
5.
Remove the air baffles that might hinder the installation in the compute module. For more
information, see "
Replacing air baffles in a compute module
."
6.
Install the drive backplane. Place the backplane against the slot and fasten the captive screw
on the backplane, as shown in
.
Figure 6-39 Installing the 4SFF drive backplane
7.
Connect cables to the drive backplane. For more information, see "
."
8.
Install the removed air baffles. For more information, see "
Replacing air baffles in a compute
9.
Install the compute module access panel. For more information, see "
10.
Install drives. For more information, see "
."
11.
Install the compute module. For more information, see "
."
12.
Install the removed security bezel. For more information, see "
13.
Connect the power cord. For more information, see "
14.
Power on the server. For more information, see "
Installing a diagnostic panel
Guidelines
You can install a diagnostic panel in compute module 1.
Install the diagnostic panel in the last drive bay of drive cage bay 1 if drive cage bay 2 is not installed
with a drive backplane. In any other conditions, install the diagnostic panel in the last drive bay of
drive cage bay 2. For more information about the locations, see "Front panel view of a compute
module."