6-5
Figure 6-6 Installing a power supply
4.
Connect the power cord. For more information, see "
Verifying the installation
Use one of the following methods to verify that the power supply is installed correctly:
•
Observe the power supply LED to verify that the power supply is operating correctly. For more
information about the power supply LED, see LEDs in "Rear panel."
•
Log in to HDM to verify that the power supply is operating correctly. For more information, see
HDM online help.
Installing a compute module
Guidelines
•
The server supports two compute modules: compute module 1 and compute module 2. For
more information, see "Front panel."
•
The server supports 24SFF and 8SFF compute modules. For more information, see "Front
panel of a compute module."
Procedure
The installation procedure is the same for 24SFF and 8SFF compute modules. This section uses an
8SFF compute module as an example.
To install a compute module:
1.
Identify the installation location of the compute module. For more information about the
installation location, see "Drive configurations and numbering."
2.
Power off the server. For more information, see "
3.
Remove the security bezel, if any. For more information, see "
4.
Press the latches at both ends of the compute module blank, and pull outward the blank, as
shown in
.