11-39
TEMP LED
LED status
Error code
Description
Flashing red
Temperature
sensor ID
A severe temperature warning is present on the
component monitored by the sensor.
This warning might occur because the temperature of the
component has exceeded the upper threshold or dropped
below the lower threshold.
CAP LED
LED status
Error code
Description
Flashing amber
01
The system power consumption has exceeded the power cap value.
Component LEDs
An alarm is present if a component LED has one of the following behaviors:
•
Flashing amber (0.5 Hz)
—A predictive alarm has occurred.
•
Flashing amber (1 Hz)
—A general alarm has occurred.
•
Flashing red (1 Hz)
—A severe alarm has occurred.
Use
to identify the faulty item if a component LED has one of those behaviors. To obtain
records of component status changes, use the event log in HDM. For information about using the
event log, see HDM online help.
Table 11-15 LED, error code and faulty item matrix
LED
Error code
Faulty item
BRD
01 PDB
02 Management
module
03 Midplane
11
Main board of compute module 1
12
Drive backplane for drive cage bay 2 of compute module 1
13
Drive backplane for drive cage bay 1 of compute module 1
21
Main board of compute module 2
22
Drive backplane for drive cage bay 4 of compute module 2
23
Drive backplane for drive cage bay 3 of compute module 2
91
mLOM Ethernet adapter
NOTE:
If the error code field displays 11 or 21 and any other code alternatively, replace the faulty
item other than the main board. If the issue persists, replace the main board.
CPU
(processor)
01
Processor 1 in compute module 1
02
Processor 2 in compute module 1
03
Processor 1 in compute module 2
04
Processor 2 in compute module 2