![H3C UniServer R6900 G3 User Manual Download Page 169](http://html2.mh-extra.com/html/h3c/uniserver-r6900-g3/uniserver-r6900-g3_user-manual_3183064169.webp)
11-10
Figure 11-3 Drive numbering for 48SFF drive configurations (48SFF server)
NOTE:
For the location of the compute modules, see "
Front panel view of the server
."
32SFF server
presents the drive configurations available for the 32SFF server and their compatible
types of storage controllers and NVMe SSD expander modules.
shows drive population
for the 32SFF server.
These drive configurations use the same drive numbering scheme, and drives with the same number
are distinguished by the compute module they reside in, as shown in
.
Table 11-8 Drive, storage controller, and NVMe SSD expander configurations (32SFF server)
Drive configuration
Storage controller
NVMe SSD expander
32SFF
(32 SFF SAS/SATA drives)
2 × storage controllers
N/A
32SFF
(28 SFF SAS/SATA drives and 4 SFF
NVMe drives)
2 × storage controllers
1 × 4-port NVMe SSD expander module
32SFF
(24 SFF SAS/SATA drives and 8 SFF
NVMe drives)
1 × storage controller
1 × 8-port NVMe SSD expander module
28SFF
(28 SFF SAS/SATA drives)
2 × storage controllers
N/A
28SFF (24 SFF SAS/SATA drives
and 4 SFF NVMe drives)
1 × storage controller
1 × 4-port NVMe SSD expander module
Table 11-9 Drive population (32SFF server)
Drive configuration
Drive cage bay 1 in
compute module 1
Drive cage bay 2 in
compute module 1
Compute module 2
32SFF
(32 SFF SAS/SATA drives)
4 SFF SAS/SATA
drives
4 SFF SAS/SATA
drives
24 SFF SAS/SATA
drives
32SFF
(28 SFF SAS/SATA drives
and 4 SFF NVMe drives)
4 SFF SAS/SATA
drives
4 SFF NVMe drives