Installing a SATA optical drive
1.
Power off the server. For more information, see "
2.
Remove the server from the rack. For more information, see "
Removing the server from a rack
."
3.
Remove the access panel. For more information, see "
."
4.
Remove the chassis air baffle. For more information, see "
5.
Remove the fan cage. For more information, see "
."
6.
Remove the security bezel, if any. For more information, see "
7.
Remove the screws that secure the drive cage bay blank over drive cage bay 1, and then push
the blank from the inside of the chassis to remove it, as shown in
Figure 90 Removing the blank in drive cage bay 1
8.
Remove the optical drive blank from the optical drive enablement option:
a.
Press the clip on the right side of the optical drive blank, as shown by callout 1 in
The optical drive blank will pop out from the enablement option.
b.
Pull the blank out of the enablement option, as shown by callout 2 in
.