Installing the access panel
1.
Press the latch on the locking lever and pull the locking lever upward, as shown in
.
If the locking lever on the access panel is locked, use a T15 Torx screwdriver to unlock the lever.
For more information, see "
."
Figure 124 Opening the locking lever
2.
Install the access panel as shown in
a.
Place the access panel on top of the server chassis, with the guide pin in the chassis
aligned with the pin hole in the locking lever area, as shown by callout 1.
b.
Close the locking lever, as shown by callout 2. The access panel will automatically slide
toward the server front to secure itself into place.
c.
(Optional.) Lock the locking lever. Use a T15 Torx screwdriver to turn the screw on the lever
90 degree clockwise, as shown by callout 3.
Figure 125 Installing the access panel