40
Operating mode
Description
system. Before setting this mode, you must delete all RAID arrays and
hot spare drives, and perform the
drives.
Auto Volume
In this mode, raw physical drives with system partitions are exposed to
the system, and physical drives without system partitions are
configured as simple volumes. Before setting this mode, you must
delete all RAID arrays and hot spare drives in the system.
Simple Volume
In this mode, only non-redundant RAID arrays with the simple volume
level (each contains only one drive) can be created. RAID arrays with
other RAID levels cannot be created. Before setting this mode, you
must delete all RAID arrays and hot spare drives in the system.
5.
Reboot the operating system to make the storage controller operating mode configuration take
effect.
Scanning drives
The storage controller might fail to timely recognize drives after the drives are hot swapped. To
solve this problem, you can scan drives.
To scan drives:
1.
On the PMC RAID management screen as shown in
, select
Logical Device
Configuration
, and press
Enter
.
Figure 67 PMC RAID management screen
2.
, select
Rescan Drives
, and press
Enter
.
Summary of Contents for UniServer B5700 G3
Page 35: ...19 Figure 29 Selecting the RAID volume to be deleted...
Page 116: ...56 Figure 96 Controller Configuration screen...
Page 220: ...61 Figure 109 Selecting Main Menu 2 Select Controller Management and press Enter...
Page 243: ...84 Figure 153 Confirming the operation...
Page 293: ...50 Figure 89 Clearing completion...
Page 382: ...21 Figure 27 Storage controller information...
Page 389: ...7 Figure 8 Identifying a storage controller 2...