12
Figure 16 Configuring RAID parameters
Table 3 Parameter description
Parameter
Description
Virtual Drive Name
RAID array name, a case-insensitive string of letters, digits, and underscores
(_).
Virtual Drive Size
Capacity for the RAID array.
Virtual Drive Size Unit
Capacity unit for the RAID array.
Stripe Size
Data block size for each drive.
Read Policy
Read cache policy:
•
Read Ahead
—Enables read ahead capability. When this capability is
enabled, the storage controller can pre-read sequential data or
anticipate data to be requested and store the data in the cache
•
No Read Ahead
—Disables read ahead capability.
Compared with the setting of the
No Read Ahead
,
Write Through
, and
Direct
values, setting the
Read Ahead
,
Write Back
, and
Cached
values can
improve performance, but at the cost of losing data consistency.
Write Policy
Write cache policy:
•
Write Through
—Enables the controller to send a data transfer
completion signal to the host when the drive subsystem has received all
data in a transaction.
•
Always Write Back
—Uses the
Write back
policy even if the
supercapacitor of the storage controller is absent or faulty. If the server
is powered off, the controller cache loses its data because of lack of
power..
•
Write Back
—Enables the controller to send a data transfer completion
signal to the host when the controller cache receives all data in a
transaction. If the supercapacitor is faulty, the
Write through
policy is
used.
Access Policy
Read and write policy:
•
Read/Write
•
Read Only
Summary of Contents for UniServer B5700 G3
Page 35: ...19 Figure 29 Selecting the RAID volume to be deleted...
Page 116: ...56 Figure 96 Controller Configuration screen...
Page 220: ...61 Figure 109 Selecting Main Menu 2 Select Controller Management and press Enter...
Page 243: ...84 Figure 153 Confirming the operation...
Page 293: ...50 Figure 89 Clearing completion...
Page 382: ...21 Figure 27 Storage controller information...
Page 389: ...7 Figure 8 Identifying a storage controller 2...