Figure 59 Selecting Manage Arrays
6.
, select the RAID array you want to view and press
Enter
to view detailed information about the RAID array (including RAID array name, level, and drive
information).
Figure 60 Selecting the target RAID array
Configuring hot spare drives
Restrictions and guidelines
In legacy mode, if a hot spare drive is configured for a RAID array, the hot spare drive will not take
effect on other RAID arrays. To avoid this problem, configure all RAID arrays and then add hot
spare drives.
Procedure
1.
On the storage controller configuration screen as shown in
, select
Array
Configuration
and press
Enter
.