Operation Manual – Information Center
H3C S5600 Series Ethernet Switches
Chapter 1 Information Center
1-9
Task
Remarks
Setting to Output System Information to the Log Buffer
Optional
Setting to Output System Information to the SNMP NMS
Optional
1.2.2 Configuring Synchronous Information Output
Synchronous information output refers to the feature that if the system information such
as log, trap, or debugging information is output when the user is inputting commands,
the command line prompt (in command editing mode a prompt, or a [Y/N] string in
interaction mode) and the input information are echoed after the output.
This feature is used in the case that your input is interrupted by a large amount of
system output. With this feature enabled, the system echoes your previous input and
you can continue your operations from where you were stopped.
Follow these steps to configure synchronous information output:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enable synchronous
information output
info-center
synchronous
Required
Disabled by default
Note:
z
If the system information is output before you input any information following the
current command line prompt, the system does not echo any command line prompt
after the system information output.
z
In the interaction mode, you are prompted for some information input. If the input is
interrupted by system output, no system prompt (except the Y/N string) will be
echoed after the output, but your input will be displayed in a new line.
1.2.3 Configuring to Display the Time Stamp with the UTC Time Zone
To add UTC time zone to the time stamp in the information center output information,
you must:
z
Set the local time zone
z
Set the time stamp format in the output direction of the information center to
date
z
Configure to add the UTC time zone to the output information
Follow these steps to configure to display time stamp with the UTC time zone: