maintenance and safety inspections
file: n:\article\cos14310m5-v1_08hpc-en\20150130_cos14310m5-v1.08hpc-en_instructions_for_use_h-p-cosmos_treadmill.doc
© 2015 h/p/cosmos sports & medical gmbh author: fh [email protected] created 30.01.2015 printed 30.01.2015 page: 122 of 216
[03]
1.
Take the tissue out of the plastic bag and
place it directly on the previously marked
position under the running belt.
2.
Press your hand on the running belt above the
tissue and move the running belt together with
the tissue for exactly 1 meter.
3.
Remove the tissue and put it into the
corresponding plastic bag. Take care that the
plastic bag is closed properly.
Repeat steps 1 to 3 for the remaining positions.
[04]
After all required steps have been performed, return the tissues to h/p/cosmos for evaluation. The tissues
will be weighed again. A weight difference indicates whether the lubrication interval needs to be adjusted.
8.4.3
Devices without UserTerminal and without automatic oil pump
Devices without a UserTerminal are equipped with an automatic acoustic signal (bleep) indicating the device
needs to be lubricated. At the standard setting, the acoustic signal will occur after every 1000 km of operation.
(Special devices may have different intervals.) After switching on the device using the main power switch, the
acoustic signal will be repeated three times: 5 times LONG (code for "0"), 1 time SHORT and 4 times LONG (code
for "1"). The device has no sensor; the oil message does not disappear automatically after lubrication.
Lubricate the running belt and running surface with the enclosed bottle of lubricant and 10 ml syringe, included in
the scope of delivery. Do not use other lubricants as they may damage the running belt and surface and cause a
breakdown of the running machine.
Please contact h/p/cosmos to order the special oil. The running belt should be lubricated after 1000 km at the
latest or/and if dry grinding noises are detected during operation. Special devices may have different intervals.
After lubrication the oil message should be reset with "OP 01". This requires an external UserTerminal or PC
software h/p/cosmos para control
®
.