DVMS 1600/800 Duplex Getting Started Guide
Document 900.0144 Rev 3.00
23
Start sequencing mode
There are three monitor outputs on the DVMS 1600/800 unit:
•
Two main monitor outputs (composite and S-Video). You can
use both these output options at the same time. They work
the same way, except that the S-Video has a sharper image
and text output.
Display options are
:
•
Full screen individual cameras—press each Camera
button (1 – 16).
•
Full screen sequence mode—press FUNCTION, then
Camera 1.
•
Quad (2 x 2) mode—press FUNCTION, then Camera
4.
•
Nine (3 x 3) mode—press FUNCTION, then Camera
9.
•
Hex (4 x 4) mode—press FUNCTION, then Camera
16.
•
One spot monitor output (analog full screen). This output
always sequences:
•
Whichever cameras are selected on the spot monitor
screen at the specified dwell rate. You cannot select an
individual camera during the sequence and it does not
display a multi-screen display.
•
Whichever cameras are not disabled on the Covert Setup
screen.
To start automatic sequencing mode:
1.
Select the cameras you wish to display and the desired display
options on the Display Setup screens (MENU
➤
System
Setup
➤
Display Setup
➤
Main Monitor/Spot
Monitor).
Examples
For full sequencing of all 16 cameras, on the main monitor
screen enable all cameras in the 1 x 1, 2 x 2, 3 x 3, and 4 x 4
fields.
To sequentially display all 16 cameras in only full screen (1 x 1)
followed by quad (4 x 4) mode, disable cameras in the 2 x 2
and 3 x 3 fields.
To sequentially display only certain cameras in full screen,
followed by 2 x 2 mode, then in 4 x 4 mode, but not in 3 x 3
mode:
•
Select those cameras you wish to display. For example, to
display only cameras 5 to12:
•
In the 1 x 1 field, deselect cameras 1 to 4 and 13 to
16.
•
In the 3 x 3 field, deselect 1 and 8.
2.
Set the desired dwell time.
3.
Accept your changes.
4.
Exit Program mode. From the Display Setup menu, press
Enter three times.