Re-Configuring the Sensor Communications Type
Whether the Artemis sensor communicates using Ethernet or serial RS422 is determined by the
position of a cable connector in relation to the Interconnection board (ICB). In order to change from
one type of communication to the other, proceed as follows.
!
Ensure that the sensor is disconnected from the power supply before removing the cover.
Take electrostatic precautions prior to touching printed circuit boards.
1. Disconnect the sensor from the power supply.
2. Remove the bottom cover.
3. Identify the data cable that runs from the external data socket down to the ICB.
4. Move its 6-way connector to the required pin header. Use the header to the left marked
“RS422” for RS422 communications, and the header to the right marked “NW1” for Ethernet
communications.
Sensor set to RS422 Communications
Sensor set to Ethernet Communications