background image

marinco.com/guest   |    800.307.6702

6

OPERATIONS MANUAL:

  6 AMP PORTABLE BATTERY CHARGER

TROUBLESHOOTING

Display

Operating Condition

Solution

Red LED 

stays on for 

more than 

24 Hrs

1.  One or more defective or 

damaged cells.

2.  On-board DC systems are 

drawing more current than 

the charger can replace.

1.   Load test the battery and replace if 

necessary.

2.  Disconnect the charger’s black 

(NEGATIVE) terminal from the battery. 

Reapply AC power and only green LED 

should now light, if so, battery may 

have been very low or too large for this 

charger. Reconnect charger & monitor 

for no more than an additional 24 

hours.

3.  Turn off all DC equipment while 

charging.

The red and 

green LED’s 

stay on for 

more than  

24 Hrs

1.  On-board DC systems are 

drawing between 1.5–5A.

2.  One or more defective or 

damaged cells.

3.  Extremely low AC voltage at 

the battery charger.

4.  Battery finishing taking 

longer than expected.

1.  Turn off all DC equipment while 

charging.

2.  Load test the battery and replace if 

necessary.

3.  Apply a higher AC voltage source or 

reduce the length of the extension 

cord.

4.  Check battery manufacturer’s specs 

on battery charging & load test battery 

after spec review.

Green LED 

stays on 

when the 

battery is 

known to be 

low

1.  Open DC output fuse.
2.  Faulty or contaminated 

terminal connections.

3.  One or more defective or 

damaged cells.

4.  May indicate a reverse 

polarity.

5.  Charger has reduced its 

output voltage below the 

normal level due to a DC 

overload or a DC short.

1.   Replace DC output fuse with a 

Bussmann (AGX-10).

2.  Clean and tighten or repair all terminal 

connections.

3.  Load test the battery and replace if 

necessary.

4.  Check for reverse polarity at 

connections.

5.  Remove the source of the overload 

or short. Reapply AC power and the 

charger should operate normally.

Red LED 

flashes on  

and off. 

Voltage may 

be low.

1.  Reverse polarity connection 

from the output terminals 

of the charger to the battery 

posts.

1.  Reconnect output terminals of 

chargers to correct battery posts, 

Positive (Red or White) charger 

terminal to positive battery post, and 

negative (Black) charger terminal to 

negative battery post.

Neither of 

the LED’s 

turn on 

when the 

AC power is 

applied

1.  No AC power available at the 

charger

2.  Component failure

1.  Connect AC power or reset the AC 

breaker on the main panel

2.  Return charger to the Guest Service 

Dept.

Summary of Contents for 2606A

Page 1: ...in the vicinity of the batteries CONNECTIONS AT A GLANCE The Guest MTC Model 2606A is designed to be used as a general purpose charger for lead acid batteries flooded cell or AGM types and gel cell b...

Page 2: ...ore using charger 1 Connect and disconnect battery leads only when supply cord is disconnected 2 For a battery installed in a vehicle first connect charger output lead to ungrounded battery post not c...

Page 3: ...iately 5 NEVER smoke or allow a spark or flame in the vicinity of the battery 6 Be extra cautious to reduce risk of dropping a metal tool onto the battery It may spark or short circuit the battery or...

Page 4: ...to reduce risk of electric shock Charger is equipped with an electric cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an outlet that is properly install...

Page 5: ...red LED s are on the 2606A is charging at the FINISHING rate stage 2 During this second charging stage the charger holds the battery voltage at approximately 14 6 VDC and then gradually reduces the am...

Page 6: ...cord 4 Check battery manufacturer s specs on battery charging load test battery after spec review Green LED stays on when the battery is known to be low 1 Open DC output fuse 2 Faulty or contaminated...

Page 7: ...CC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiat...

Page 8: ...ed at marinco com limited warranty Marinco is a proven industry leader with a Global network of sales distribution and service Product concerns as related to Form Fit and Function may be submitted onl...

Page 9: ...roximit des batteries APER U DES CONNEXIONS Le Guest MTC Mod le 2606A est con u pour tre utilis comme un chargeur d usage g n ral pour des batteries d accumulateurs au plomb types lectrolyte liquide o...

Page 10: ...S DU SOL AVERTISSEMENT RISQUE DE M LANGE DE GAZ EXPLOSIFS Lire les instructions du manuel avant d utiliser le chargeur 1 Ne brancher et ne d brancher les c bles de la batterie que lorsque le cordon d...

Page 11: ...batterie 4 Si l acide de la batterie entre en contact avec la peau ou les v tements laver imm diatement l eau et au savon Si l acide p n tre dans les yeux rincer imm diatement les yeux avec de l eau...

Page 12: ...orrespond la sortie nominale du chargeur de batterie Pr cautions de branchement c a et de mise la terre DANGER NE PAS UTILISER LE CHARGEUR AVEC UN ADAPTATEUR A DEUX LAMES OU UNE RALLONGE CETTE UTILISA...

Page 13: ...Amp Tandis que le DEL rouge est allum la tension mesur e avec le chargeur sous tension sera approximativement 11 8 14 Volt Si le DEL rouge reste allum pendant plus de 24 heures vous reporter au Probl...

Page 14: ...elatives la charge de la batterie et tester la charge de la batterie apr s avoir v rifi les sp cifications Le DEL vert reste allum lorsque la batterie est en fait faible 1 Fusible de sortie CC ouvert...

Page 15: ...rtie 15 des R glementations de la FCC Ces limites sont tablies pour assurer une protection raisonnable contre les brouillages nuisibles lorsque l quipement est utilis dans un environnement commercial...

Page 16: ...rranty Marinco est un leader reconnu du secteur qui poss de un r seau mondial de vente de distribution et de service Les questions concernant la forme l installation et la fonction du produit peuvent...

Reviews: