background image

marinco.com/guest   |    800.307.6702

5

OPERATIONS MANUAL:

  6 AMP PORTABLE BATTERY CHARGER

DC Connection Precautions

1)  Connect and disconnect DC output clips only after removing AC cord from electric 

outlet. Never allow the DC output clips to touch each other.

2)  Check polarity of the battery posts. The POSITIVE (POS., P, +) battery post usually 

has a larger diameter than the NEGATIVE (NEG., N, -) post. 

3)  Connect Red charger output wire to POSITIVE post, Black charger wire to NEGATIVE. 

See below diagrams for more details.

4)  Do not face the battery when making the final connection.

OPERATING THE CHARGER

The LED Function Chart below describes the charging process.

ON

OFF

Condition

Red

Green

When the red LED is on, it indicates that your battery is 

discharged and the 2606A is recharging at the "BULK" rate  

(stage 1). This charging rate is 6 Amps. 
While the red LED is on, the voltage measured (with the charger 

on) will be approx. 11.8 to 14 Volts.
If the red LED stays on for more than 24 hours, refer to Problem 

1 in the troubleshooting section in this manual.

Red & 

Green

None

When both the green and the red LED’s are on, the 2606A is 

charging at the "FINISHING" rate. (stage 2). During this second 

charging stage, the charger holds the battery voltage at 

approximately 14.6 VDC, and then gradually reduces the amount 

of current (Amps) it delivers to the battery. By doing this, the 

battery is able to “absorb” the last 10% of charge as quickly as 

possible without becoming overheated.
If both LED’s stay on longer than 24 hours, refer to Problem 2 in 

the troubleshooting section in this manual.

Green

Red

When the green LED is on, the 2606A is charging at a "FLOAT” 

or “MAINTENANCE" rate of less than 1.5 Amps, (stage 3). Your 

battery is now 90% charged and ready for use. This "float" 

charging current will gradually decrease to as low as 0.1 Amps 

as the battery reaches 100% charge. It will now be kept at full 

charge without over-charging.
If the green LED stays on when your battery is known to be low, 

refer to Problem 3 in the troubleshooting section in this manual.

Red 

Flashing

Green

When the red LED is flashing on and off, the 2606A is connected 

in reverse polarity (positive charger output terminal to negative 

battery post and negative charger output terminal to positive 

battery post). This means the charger is disabled and no current 

is being delivered to the battery or battery voltage below 4V. 

 

Summary of Contents for 2606A

Page 1: ...in the vicinity of the batteries CONNECTIONS AT A GLANCE The Guest MTC Model 2606A is designed to be used as a general purpose charger for lead acid batteries flooded cell or AGM types and gel cell b...

Page 2: ...ore using charger 1 Connect and disconnect battery leads only when supply cord is disconnected 2 For a battery installed in a vehicle first connect charger output lead to ungrounded battery post not c...

Page 3: ...iately 5 NEVER smoke or allow a spark or flame in the vicinity of the battery 6 Be extra cautious to reduce risk of dropping a metal tool onto the battery It may spark or short circuit the battery or...

Page 4: ...to reduce risk of electric shock Charger is equipped with an electric cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an outlet that is properly install...

Page 5: ...red LED s are on the 2606A is charging at the FINISHING rate stage 2 During this second charging stage the charger holds the battery voltage at approximately 14 6 VDC and then gradually reduces the am...

Page 6: ...cord 4 Check battery manufacturer s specs on battery charging load test battery after spec review Green LED stays on when the battery is known to be low 1 Open DC output fuse 2 Faulty or contaminated...

Page 7: ...CC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiat...

Page 8: ...ed at marinco com limited warranty Marinco is a proven industry leader with a Global network of sales distribution and service Product concerns as related to Form Fit and Function may be submitted onl...

Page 9: ...roximit des batteries APER U DES CONNEXIONS Le Guest MTC Mod le 2606A est con u pour tre utilis comme un chargeur d usage g n ral pour des batteries d accumulateurs au plomb types lectrolyte liquide o...

Page 10: ...S DU SOL AVERTISSEMENT RISQUE DE M LANGE DE GAZ EXPLOSIFS Lire les instructions du manuel avant d utiliser le chargeur 1 Ne brancher et ne d brancher les c bles de la batterie que lorsque le cordon d...

Page 11: ...batterie 4 Si l acide de la batterie entre en contact avec la peau ou les v tements laver imm diatement l eau et au savon Si l acide p n tre dans les yeux rincer imm diatement les yeux avec de l eau...

Page 12: ...orrespond la sortie nominale du chargeur de batterie Pr cautions de branchement c a et de mise la terre DANGER NE PAS UTILISER LE CHARGEUR AVEC UN ADAPTATEUR A DEUX LAMES OU UNE RALLONGE CETTE UTILISA...

Page 13: ...Amp Tandis que le DEL rouge est allum la tension mesur e avec le chargeur sous tension sera approximativement 11 8 14 Volt Si le DEL rouge reste allum pendant plus de 24 heures vous reporter au Probl...

Page 14: ...elatives la charge de la batterie et tester la charge de la batterie apr s avoir v rifi les sp cifications Le DEL vert reste allum lorsque la batterie est en fait faible 1 Fusible de sortie CC ouvert...

Page 15: ...rtie 15 des R glementations de la FCC Ces limites sont tablies pour assurer une protection raisonnable contre les brouillages nuisibles lorsque l quipement est utilis dans un environnement commercial...

Page 16: ...rranty Marinco est un leader reconnu du secteur qui poss de un r seau mondial de vente de distribution et de service Les questions concernant la forme l installation et la fonction du produit peuvent...

Reviews: