65
Expert Power Control 8221/8226
© 2022 GUDE Systems GmbH
Specifications
epc8226Current
.58.1.5.1.2.1.5.x
Gauge32
RO
Actual Curent on Pow er Channel.
epc8226Voltage
.58.1.5.1.2.1.6.x
Gauge32
RO
Actual Voltage on Pow er Channel
epc8226Frequency
.58.1.5.1.2.1.7.x
Gauge32
RO
Frequency of Pow er Channel
epc8226Pow erFactor
.58.1.5.1.2.1.8.x
Integer32
RO
Pow er Factor of Channel betw een -1.0 and 1.00
epc8226Pangle
.58.1.5.1.2.1.9.x
Integer32
RO
Phase Angle betw een Voltage and L Line Current betw een -180.0 and
180.0
epc8226Pow erApparent
.58.1.5.1.2.1.10.x
Integer32
RO
L Line Mean Apparent Pow er
epc8226Pow erReactive
.58.1.5.1.2.1.11.x
Integer32
RO
L Line Mean Reactive Pow er
epc8226AbsEnergyReactive
.58.1.5.1.2.1.12.x
Gauge32
RO
Absolute Reactive Energy counter.
epc8226AbsEnergyActiveResetta
ble
.58.1.5.1.2.1.13.x
Gauge32
RW
Resettable Absolute Active Energy counter. Writing '0' resets all
resettable counter.
epc8226AbsEnergyReactiveReset
table
.58.1.5.1.2.1.14.x
Gauge32
RO
Resettable Absolute Reactive Energy counter.
epc8226ResetTime
.58.1.5.1.2.1.15.x
Gauge32
RO
Time in seconds since last Energy Counter reset.
epc8226Forw EnergyActive
.58.1.5.1.2.1.16.x
Gauge32
RO
Forw ard Active Energy counter.
epc8226Forw EnergyReactive
.58.1.5.1.2.1.17.x
Gauge32
RO
Forw ard Reactive Energy counter.
epc8226Forw EnergyActiveResett
able
.58.1.5.1.2.1.18.x
Gauge32
RO
Resettable Forw ard Active Energy counter.
epc8226Forw EnergyReactiveRes
ettable
.58.1.5.1.2.1.19.x
Gauge32
RO
Resettable Forw ard Reactive Energy counter.
epc8226RevEnergyActive
.58.1.5.1.2.1.20.x
Gauge32
RO
Reverse Active Energy counter.
epc8226RevEnergyReactive
.58.1.5.1.2.1.21.x
Gauge32
RO
Reverse Reactive Energy counter.
epc8226RevEnergyActiveResetta
ble
.58.1.5.1.2.1.22.x
Gauge32
RO
Resettable Reverse Active Energy counter.
epc8226RevEnergyReactiveResett
able
.58.1.5.1.2.1.23.x
Gauge32
RO
Resettable Reverse Reactive Energy counter.
epc8226LineSensorName
.58.1.5.1.2.1.100.x
OCTETS
RW
A textual string containing name of a Line Sensor
epc8226OVPIndex
.58.1.5.2.1.1.x
Integer32
RO
None
epc8226OVPStatus
.58.1.5.2.1.2.x
INTEGER
RO
show s the status of the built-in Overvoltage Protection
epc8226spActivePow erChan
.58.1.5.5.1.0
Unsigned32
RO
Number of Single Port Pow er Channels. Value is zero on EPC 8220
series.
epc8226spPow erIndex
.58.1.5.5.2.1.1.x
Integer32
RO
Index of Single Port Pow er Channel entries. Indices 0-5 mean Ports A1
to A6, 6-11 are Ports B1 to B6.
epc8226spChanStatus
.58.1.5.5.2.1.2.x
Integer32
RO
0 = data not active, 1 = data valid
epc8226spAbsEnergyActive
.58.1.5.5.2.1.3.x
Gauge32
RO
Absolute Active Energy counter.
epc8226spPow erActive
.58.1.5.5.2.1.4.x
Integer32
RO
Active Pow er
epc8226spCurrent
.58.1.5.5.2.1.5.x
Gauge32
RO
Summary of Contents for Expert Power Control 8221 Series
Page 2: ...2 Expert Power Control 8221 8226 2022 GUDESystems GmbH ...
Page 5: ...Device Description ...
Page 14: ...Operating ...
Page 25: ...Configuration ...
Page 54: ...Specifications ...
Page 109: ...Support ...