Configuration
If you create a complex timer or change an existing timer, you will always see an exten-
ded dialog. Here, ports can be switched as well as other actions can be executed via
CLI commands. The setting of the switching times is more granular.
You can see here the extended representation of the first rule of the simple timer from
the previous example. The action is started every day of every month at 9:30. The week-
days Saturday and Sunday are excluded. An existing rule can be removed with the "De-
lete" button.
If a rule is deleted, the following rules move up. The numbering of the following rules
also changes by one. This also applies to the index in the console commands.
A simple timer is directly "enabled", for a newly created complex timer "enable trigger"
must be switched on manually. You can set a probability and a jitter for the timer rules.
This makes random events possible. In this example the rule is executed with 100%
probability. A jitter of 0 means that the action takes place exactly at the programmed
time. Ports are switched as action mode, alternatively a console command (CLI Cmd)
can be executed.
After changes to existing timers, the "Rule Name" may no longer be meaningful. To
keep the overview, it may be useful to adjust the name.