snmp snmpv3 authalg set {NONE=0|MD5=1|
SHA1=2|SHA256=3|SHA384=4|SHA512=5}
sets SNMP v3 authentication
snmp snmpv3 authalg show
show SNMP v3 authentication algorithm
snmp snmpv3 privalg set {NONE=0|DES=1|
3DES=2|AES128=3|AES192=4|AES256=5|
AES192*=6|AES256*=7}
sets SNMP v3 privacy algorithm
snmp snmpv3 privalg show
show SNMP v3 privacy algorithm
snmp snmpv3 authpassw d set "{passw d}"
sets SNMP v3 authentication passw ord
snmp snmpv3 privpassw d set "{passw d}"
sets SNMP v3 privacy passw ord
snmp snmpv3 authpassw d hash set "{passw d}" sets SNMP v3 authentication hashed passw ord
snmp snmpv3 privpassw d hash set "{passw d}" sets SNMP v3 privacy hashed passw ord
snmp trap type set {NONE=0|V1=1|V2=2|V3=3}
sets type of SNMP traps
snmp trap type show
show SNMP trap type
snmp trap receiver {trap_num} set "{dns_name}"
sets address and port of SNMP trap receiver
{trap_num}
snmp trap receiver {trap_num} show
show address and port of SNMP trap receiver
{trap_num}
syslog
enters cmd group "syslog"
syslog enabled set {OFF=0|ON=1}
enables syslog msgs on/off
syslog enabled show
show if syslog enabled
syslog server set "{dns_name}"
sets address of syslog server
syslog server show
show s address of syslog server
system
enters cmd group "system"
system beeper manual set {OFF=0|ON=1}
{millisec}
manually sets beeper w ith optional duration
system beeper manual show
show s beeper state
system restart
restarts device
system fabsettings
restore fab settings and restart device
system bootloader
enters bootloader mode
system flushdns
flush DNS cache
system uptime
number of seconds the device is running
system name show
show s device name
system version show
show s actual firmw are version
system display {disp_num} default extsensor
{port_num} {sen_type} set {sen_field}
show s external sensor
system display {disp_num} default linesensor
{line_num} set {sen_field}
show s energy line sensor
system display {disp_num} default portsensor
{port_num} set {sen_field}
show s energy port sensor
system display {disp_num} default set
{BLANK=0,LOCAL_TIME=1,UTC_TIME=2}
show s other contents
system display {disp_num} default show
show s default setting for display
system display default hash set "{data}"
sets hashed display setting
system display default hash show
show s hashed display setting
system {SWITCH_PORT=0} events set {OFF=0|
ON=1}
enable global events
system {SWITCH_PORT=0} events show
show s if global events enabled
system {SWITCH_PORT=0} events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2,E
VT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER=5,E
VT_DISPLAY=6,EVT_CONSOLE=7,EVT_MQTT=8}
"
enables different event types
system {SWITCH_PORT=0} events type show
show s w hat event types are enabled
system {SWITCH_PORT=0} events mqtt retain set
{OFF=0|ON=1}
sets mqtt retain
system {SWITCH_PORT=0} events mqtt retain
show
show s if mqtt retain set
system panel enabled set {OFF=0|ON=1}
blocks panel buttons w hen not enabled
system panel enabled show
show s if panel buttons are enabled
system panel port all set {OFF=0|ON=1}
enable siw tch all relays from panel buttons
system panel port all show
show s if siw tch all relays from panel buttons
enabled
system sensor {VSYS=0|VAUX=1|VMAIN=2|
TCPU=3} show
show s internal sensors if model supports it