background image

 

– 1 – 

AtlasSound.com

Specifications are subject to change without notice.

Owner’s Manual

AP-S20RT

AC Distribution & Suppressor Unit

1601 Jack McKay Blvd. • Ennis, Texas 75119  U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

AP-S20RT

AC Power Distribution &  

AC Suppressor Unit with Remote Activation

Summary of Contents for AP-S20RT

Page 1: ...ect to change without notice Owner s Manual AP S20RT AC Distribution Suppressor Unit 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 AP S20RT AC Power Distribution AC Suppressor Unit with Remote Activation ...

Page 2: ...k McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Table of Contents Important Safety Instructions 3 Introduction 5 Key Features and Applications 6 Front Panel Description 7 Rear Panel Description 8 Installation and Remote Turn On Configuration 9 AC Power Cord Retainer System 10 Specifications 11 Warranty 12 ...

Page 3: ...cart stand tripod bracket or table specified by the manufacturer or sold with the device When a cart is used use caution when moving the cart device combination to avoid injury from tip over 13 Unplug this device during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the device has been damaged in any way suc...

Page 4: ...allation Do not touch the 70V speaker terminals as electric shock may result Ensure that the safety ground terminal is connected to a proper ground Never connect the ground to a gas pipe as a catastrophic disaster may result Be sure the installation of the product is stable avoid slanted surfaces as the product may fall and cause injury or property damage When InstallingThe Product Plugging in or ...

Page 5: ...witched outlets to protect equipment A rear mounted bypass switch disables the Remote Activation should the need arise The AP S20RT features noise filtering for unwanted Radio Frequency Interference RFI that is commonly introduced into AC lines by nearby radio transmitters or wireless products EMI filters are incorporated to reduce noise and Electromagnetic Interference EMI from such items as elec...

Page 6: ...uitry RFI Noise Filtering to Reduce Radio Frequency Interference EMI Filtering to Reduce Electromagnetic Interference Circuit Breaker Protection 20A Front Mounted USB Charger Light Port Rear Mounted XLR Connector For 12VDC LED Lamp AP GNL18 Lamp Sold Separately Spike Suppression Up To 6000V AC Fault Indicator AC Power Cord Retainer System Applications The flexible AP S20RT was designed with featur...

Page 7: ...oducts Some devices require licensed charging circuitry 5 Power ON Indicator Will illuminate Blue when the AC Mains Power Switch is in the ON Position 6 AC Fault Indicator Although the Clamping Suppression circuit virtually assures protection from most transient voltage spikes and surges Nature has a way of occasionally creating electrical forces that are beyond the capabilities of any device to a...

Page 8: ...er for the optional AL GNL18 light 4 Light Socket Power Switch Two position switch to power On Off the XLR light socket 5 Remote Activation There are two methods to remotely activate the AP S20RT A External Switch The Ext SW terminals are connected to a latching type dry contact closure to activate the AP S20RT Note The Remote Bypass switch must be shorted for Remote Activation This feature can be...

Page 9: ...use Rack Rail type screws of 10 32 x 1 Always make sure the 20A outlet is properly inspected by a certified electrician prior to connecting the AP S20RT Make sure to inspect the equipment that will be connected to the AP S20RT to ensure it does not exceed 20A total amperage draw Remote Activation Connections Diagram Remote Activation via Hard Contact Switch Use External Key or Panel Switch Hard Co...

Page 10: ...ower Cord Retainer System This system prevents the power cord from being removed without the use of a screwdriver Follow these steps for installation Note Installation of this product must be done by a certified electrician 1 Locate the 6 32 screw retainer clip and zip tie 2 Locate the AC wall outlet that will be used to power the Atlas Power product Remove the center screw securing the cover plat...

Page 11: ...ch Two position On Off Remote Activation Latching Type Dry Contact Closure or 5V 24VDC Remote Activation Connector 4 Position 3 5mm Phoenix Type Connection AC Mains Power Cord 9 2 74m 12 Gauge 20A Male AC Plug Technical Data Current Rating 20 Amps Operating Voltage 102VAC 132VAC Power Consumption 8 Watts Min Spike Clamping Voltage 460VRMS 3 000A Max Spike Clamping Voltage 6000V Max Spike Clamping ...

Page 12: ...f purchase under the terms of this warranty All warranty returns must comply with our returns policy set forth below When products returned to Atlas Sound do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is included with the returned product s a written request for an estimate of repair costs before any non...

Reviews: