P/N G610B
April, 2016 (Rev 0)
Page 7
DETECTION SENSOR ASSEMBLY
(P/N G605)
The sensor assembly, which is temperature activated, consists of two sensors mounted in a high temperature silicone
rubber sleeve. The rubber sleeve contains magnets running along its length that allow for easy installation on the
front edge of the underside of the hood or microwave-hood.
The detection sensor assembly (p/n G605) is to be
installed where normal ambient cooking temperatures do not exceed 300 deg. F (148.8 deg. C).
The distribution assembly consists of one housing and
cover with a stainless steel braided hose coming out of it.
The stainless steel braided hose has a quick connect fitting
installed on the end for easy connection to the valve head
of the extinguisher. Inside the housing there are 2 nozzles
mounted in fittings connected by a stainless steel tube.
The assembly is installed underneath the hood against the
wall. The Nozzles angle shall be adjusted based on the
distribution assembly’s height above the cooking surface.
The nozzles/hose assembly can be removed and reinstalled
with the hose coming out the opposite side of the housing
depending on installation requirements.
Note:
The stainless steel braided hose with quick
connect shall be on the same side of the
distribution
assembly
as
the
system
enclosure, i.e., if the hose is on the left side
of the distribution assembly, enclosure shall
be mounted inside the cabinetry above the
microwave hood / range hood on the far left
side or vice versa for the right side.
DISTRIBUTION ASSEMBLY
(P/N G604-A)
FIGURE 4
Permit Number: