42
Locking drive
Assembly and operating instructions
ELTRAL VAN
10.2013 | G28230 | Printed in Germany
DE
EN
The drive must be connected to a voltage of 24 V DC (direct current).
To convert the mains voltage 230 V ~, 50 Hz or other) into 24 V DC, you
must use a power supply unit whose technical data corresponds to the
information on the drive‘s type label. The power supply unit must meet the
requirements of security class II.
When making the electric connection, the following points must be
observed in all cases:
The connection of the opening drive depends on the opening direction
of the sash.
In order to avoid damage, when putting into operation, we recommend
that the 24 V control voltage is applied only when the sash is opened,
the locking plate is removed and the opening drive has been hung-out.
Putting into operation with the connector attached reverse leads to the
destruction of the electrics.
When connecting and putting into operation, always observe the
operating instructions of the window drive.
3.4.1 Electrical connection