33
Generation 3 Visual Feedback
Symptom
Diagnosis
Check:
Status (clear)
1 blink
Cycle Terminal
Shorted
Disconnect the push button, keypad, intercom keypad, or any other accessory
wired to this terminal. Try the remote. If the remote works, then the problem is
the accessory.
Status (clear)
2 blinks
Safety Terminal
Shorted
Disconnect the loop detector, photo beam, or any other accessory wired to this
terminal. Try the remote. If the remote works, the problem is the accessory.
Status (clear)
3 blinks
Exit Terminal
Shorted
Disconnect exit wand, loop detector, photo beam, Knox box, or any other accessory
wired to this terminal. Try remote. If the remote works, the problem is the
accessory.
Status (clear)
4 blinks
Shadow Terminal
Shorted
Disconnect the loop detector, photo beam, or any other accessory wired to this
terminal. Try remote. If the remote works, the problem is the accessory.
Status (clear)
5 blinks
Close Edge
Terminal Shorted
Disconnect the edge sensor, photo beam, or any other accessory wired to this
terminal. Try the remote. If the remote works, the problem is the accessory.
Status (clear)
6 blinks
Open Edge
Terminal Shorted
Disconnect edge sensor, photo beam, or any other accessory wired to this terminal.
Try the remote. If the remote works, the problem is the accessory.
RF (yellow)
Flickers
Receiving 318
MHz RF
Normal operation when remote or wireless keypad is used.
RF (yellow)
OFF
No 318 MHz RF
Received
•
Battery in Remote
•
Program Remote
•
Antenna Receiver Connections
•
Antenna Receiver
Power (green)
ON
AC or Solar
Power Present
Normal Operation
Power (green)
OFF
No AC or Solar
Power
Transformer:
•
Breaker or GFI
•
Power at AC outlet.
•
Output of Transformer.
•
Voltage on wire at 18 VAC Input
Solar:
•
Solar Panel Wires Reversed
•
Weather
•
Solar Panel Placement
•
Output of Solar Panel
•
Voltage on wire at Solar Input
Charge (red)
ON
Fast Charging
Mode
Battery Voltage should be ~14.8 VDC when connected to the circuit board
Charge (red)
Fast Blinking
Soak Charging
Mode
Battery Voltage should be ~14.1 VDC when connected to the circuit board
Charge (red)
Slow Blinking
Float Charge
Battery Voltage should be ~13.8 VDC when connected to the circuit board
Charge (red)
OFF
Battery Not
Being Charged
AC power
Transformer
Solar Panel – Check Weather
Charging Circuit