27
GRN
C
OM
C
OM
CYCLE
CLOSE
SAFETY
SHADOW
LOOP
CLOSE
EDGE
OPEN
EDGE
EXIT
OPEN
BLK
RECEIVER
RED
25
FUSE
B
A
T
T+
B
A
T
T-
1 2
3
4
ON
DIP
S
TA
T
U
S
LE
A
R
N
R
M
T
R
E
C
E
IV
E
R
LE
A
R
N
M
A
S
T
L
IM
IT
LE
A
R
N
S
LV
L
IM
IT
S
3
S
4
A
LM
S
2
O
FF
S
O
FT
S
TA
R
T
O
FF
W
A
R
N
IN
G
O
FF
O
P
E
N
P
U
LL
S
LV
O
P
E
N
D
LY
.
M
O
D
E
1
O
FF
M
O
D
E
2
O
FF
O
N
O
N
P
U
S
H
S
IM
U
LT
.
O
N
O
N
1
2
0
M
IN
M
A
X
C
H
A
R
G
IN
G
P
W
R
I
N
OR
G
BL
UE
WHT
GRN
BRN
RED
MASTER INPUT
S
BLK
SOL
AR
or
18
V
A
C
OR
G
BL
UE
WHT
GRN
BRN
RED
SL
A
VE INPUT
S
BLK
LOCK GT
O
A
UX
G
TO
T
R
A
N
S
F
LO
C
K
P
W
R
A
U
X
R
LY
P
O
W
E
R
IN
P
U
T
S
C
O
N
T
R
O
L
O
U
T
P
U
T
S
M
A
S
T
E
R
C
A
B
LE
S
LA
V
E
C
A
B
LE
C
O
N
T
R
O
L I
N
P
U
T
S
A
UT
O CL
OSE
TIME
ST
ALL FOR
CE
1
2
3
4
7
5
6
NOTE:
• All control inputs are dry-contact, normally open, inputs. DO NOT apply external voltage sources to these inputs.
• All inputs are connected with respect to
COMMON
terminal.
• The status LED will blink once when its corresponding input is activated.
1 COM:
Circuit common (reference for all logic input)
• Two (2) terminals to provide extra common connection point.
2 CYCLE CLOSE:
(Typically for use with doorbell button or hardwired key pad)
• Each activation at this input will cycle the operation as follows:
….→ OPEN → STOP → CLOSE → STOP → OPEN → …
3 SAFETY:
(Typically for use with photo beam device, loop detector
or other non-contact sensors)
• Activation of this input while the gate is closing will cause the gate to
stop and return to the opened position.
• Activation of this input while the gate is opening has no effect (gate
will continue to open).
• Activation of this input while gate is idle will prevent gate from closing.
4 EXIT/OPEN:
(Typically for use with exit loop or wand)
• Activation of this input will open the gate if it’s not already at the
open position
• Activation of this input while at open limit will restart the auto close time
(if enabled).
5 SHADOW LOOP:
(Typically for use with loop detector device)
• This input is only monitored when the gate is at the fully open
position. At any other position, activation of this input has no effect on
gate operation.
• Activation of this input while gate at the fully open position will
prevent gate from closing.
6 CLOSE EDGE:
(Typically for use with safety edge device)
• Activation of this input while the gate is closing will cause the gate to
stop and reverse direction for approximately 2 seconds.
• Activation of this input while the gate is opening has no effect (gate will continue to open).
• Activation of this input while gate is idle will prevent gate from closing.
7 OPEN EDGE:
(Typically for use with safety edge device)
• Activation of this input while the gate is opening will cause the gate to
stop and reverse direction for approximately 2 seconds.
• Activation of this input while the gate is closing has no effect (gate
will continue to close).
• Activation of this input while gate is idle will prevent gate from opening.
Connecting Accessories
Input Connections