12. Autoflow Series Drying Rates
36
PNEG-696
TopDry Series 2000 Autoflow
Shelled Corn
(Metric Measurements)
Autoflow Series
9.14 m
Dia.
2 Fan
10.97 m
Dia.
1 Fan
10.97 m
Dia.
2 Fan
Fan and
Heater
Unit(s)
Plenum
Temperature
C°
Moisture
Content
Wet
Basis
MT / hr
Minutes
Between
Dumps
MT / hr
Minutes
Between
Dumps
MT / hr
Minutes
Between
Dumps
11.19 kW
91.44 cm
1.125
Million
kCal
71
20%
23.9
18.9
25.2
25.8
25%
15.1
29.9
16.0
40.7
30%
9.4
47.9
10.0
65.2
82
20%
30.5
14.8
32.3
20.1
25%
19.3
23.4
20.4
31.8
30%
12.1
37.4
12.8
51.0
93
20%
35.7
*12.6
37.8
*17.2
25%
22.6
*19.9
24.0
*27.2
30%
14.1
*32.0
15.0
*43.5
11.19 kW
101.60 cm
1.5
Million
kCal
71
20%
29.3
15.4
32.2
20.2
25%
18.6
24.3
20.4
31.9
30%
11.6
39.0
12.8
51.1
82
20%
37.5
12.0
41.2
15.8
25%
23.8
19.0
26.1
24.9
30%
17.8
30.4
16.3
39.9
93
20%
*43.9
*10.2
*48.3
*13.4
25%
*27.8
*16.2
*30.6
*21.3
30%
*17.4
*26
*19.1
*34.1
22.37 kW
106.68 cm
2.5
Million
kCal
71
20%
20.8
31.3
36.9
17.6
25%
13.2
49.4
23.4
27.8
30%
8.2
79.1
14.6
44.6
82
20%
26.6
24.4
47.2
13.8
25%
16.9
38.6
29.9
21.7
30%
10.5
61.8
18.7
34.8
93
20%
31.2
20.8
55.3
11.7
25%
19.7
32.9
35.0
18.6
30%
12.3
52.8
21.9
29.8
29.83 kW
106.68 cm
2.5
Million
kCal
71
20%
24.1
26.9
25%
15.3
42.6
30%
9.6
68.2
82
20%
30.9
21.0
25%
19.6
33.3
30%
12.2
53.3
93
20%
36.2
18.0
25%
22.9
28.4
30%
14.3
45.5
Insufficient burner BTUs for 7°C ambient temperature Ratings exclude loading time.
Est. at ambient temperature 7°C, rel.humidity 65%. Use only as a guide, conditions will vary capacities.
1/4 CFM/BU cooling rate.