PNEG-696
TopDry Series 2000 Autoflow
35
12. Autoflow Series Drying Rates
Shelled Corn
(Metric Measurements)
Autoflow Series
6.40 m
Dia.
1 Fan
7.32 m
Dia.
1 Fan
9.14 m
Dia.
1 Fan
Fan and
Heater
Unit(s)
Plenum
Temperature
C°
Moisture
Content
Wet
Basis
MT/Hr
Minutes
Between
Dumps
MT/Hr
Minutes
Between
Dumps
MT/Hr
Minutes
Between
Dumps
11.19 kW
91.44 cm
1.125
Million
kCal
71
20%
12.7
17.4
13.4
21.6
14.1
31.9
25%
8.0
27.6
8.5
34.1
9.0
50.4
30%
5.0
44.2
5.3
54.6
5.6
80.8
82
20%
16.2
13.6
17.1
*16.8
18.1
*24.9
25%
10.3
21.5
10.9
*26.6
11.5
*39.4
30%
6.4
34.5
6.8
*42.6
7.2
*63.1
93
20%
19.0
*11.6
20.1
*14.4
21.2
*21.3
25%
12.0
*18.4
12.7
*22.7
13.4
*33.6
30%
7.5
*29.5
8.0
*36.4
8.4
*53.9
11.19 kW
101.60 cm
1.5
Million
kCal
71
20%
14.8
14.9
16.5
17.5
18.1
25.0
25%
9.4
23.5
10.4
27.7
11.4
39.5
30%
5.9
37.7
6.5
44.4
7.1
63.3
82
20%
19.0
11.6
*21.1
*13.7
*23.1
*19.5
25%
12.0
18.4
*13.3
*21.6
*14.6
*30.9
30%
7.5
29.5
*8.3
*34.7
*9.1
*49.5
93
20%
*22.2
*9.9
*24.7
*11.7
*27.1
*16.7
25%
*14.1
*15.7
*15.6
*18.5
*17.1
*26.4
30%
*8.8
*25.2
*9.8
*29.6
*10.7
*42.2
22.37 kW
106.68 cm
2.5
Million
kCal
71
20%
18.8
15.4
20.5
22.0
25%
11.9
24.3
13.0
34.8
30%
7.4
38.9
8.1
55.8
82
20%
21.1
12.0
26.2
17.2
25%
15.2
19.0
16.6
27.2
30%
9.5
30.4
10.4
43.6
93
20%
28.2
10.2
30.7
14.7
25%
17.8
16.2
19.4
23.2
30%
11.2
25.9
12.1
37.2
29.83 kW
106.68 cm
2.5
Million
kCal
71
20%
23.4
19.3
25%
14.8
30.5
30%
9.2
48.9
82
20%
29.9
15.1
25%
18.9
23.8
30%
11.8
38.2
93
20%
35.0
12.9
25%
22.2
20.3
30%
13.8
32.6
Insufficient burner BTUs for 7°C ambient temperature Ratings exclude loading time.
Est. at ambient temperature 7°C, rel.humidity 65%. Use only as a guide, conditions will vary capacities.
1/4 CFM/BU cooling rate.