21
INSTALLATION
Aspirator
Breaker
Aspirator
Contactor
Aspirator
Overload
Jumper wires to top
of unload breaker
Wires go to wires on
unload contactor coil
J8-9
J8-16
Leads from Aspirator blower motor
com
n/o
Breakers
240 volt 1 ph - 60 amp
240 volt 3 ph - 60 amp
380 volt 3 ph - 50 amp
460 volt 3 ph - 50 amp
Contactors
240 volt 1 ph - 60 amp
240 volt 3 ph - 50 amp
380 volt 3 ph - 40 amp
460 volt 3 ph - 40 amp
Wire Sizes
240 volt 1 ph - 10 ga.
240 volt 3 ph - 10 ga.
380 volt 3 ph - 10 ga.
460 volt 3 ph - 10 ga.
Heater Strips
240 volt 1 ph - C214B
240 volt 3 ph - C104B
380 volt 3 ph - C592A
460 volt 3 ph - C526A
Control Option for the Aspirator
The Aspirator can be wired to the control circuits of the dryer.
This wiring allows the Aspirator to run only when the augers of
the dryer run. When the dryer experiences a safety shutdown, the
Aspirator will shutdown also.
Use this diagram to install the
Aspirator Control Option.
orange
white