12
Mount the T-valve Outer Can
Weldment to the inlet side of
the blower.
Place the
Blower Inlet Plate Weldment
onto the
3 hp Blower Unit
.
It should fit over the studs on the inlet side of the blower.
Place the
T-valve Outer Can Weldment
over the studs and the
Blower
Inlet Plate Weldment
so the angle ring is at the top of the assembly.
Secure with the
3/8" Whiz Nuts
provided.
Complete the T-valve
Assembly.
IF the
PR-331 Handle
is not installed on the
T-Valve Inner Can Weldment,
THEN install it now with the
5/16" Whiz Nuts and Bolts
provided.
Insert the
T-valve Inner Can Weldment
into the outer can weldment.
Bolt the
T-Valve Handle End Plate
to the T-valve assembly using the
5/16"
Whiz Nuts and Bolts
provided.
Check that the
T-valve Inner Can Weldment
rotates freely in the assembly.
IF the can does not rotate freely,
THEN check for interference between cans, check roundness of cans, or add
some grease to help rotation.
INSTALLATION
Inside of the T-valve Assembly.
Assembling the T-valve.
Expanded Aspirator
The Expanded Aspirator uses a
rotary valve to control the direction
of the suction force generated by the
blower. It can be set for top only,
bottom only, or top and bottom
suction. The valve mounts directly
to the blower for simple mounting.
Simple mounting of the T-valve and 3 hp Blower combination.