13
Installing the Blower
Expanded Aspirator
The 3 hp Blower Unit generates the
vacuum force needed to extract the
debris from the discharging grain.
Preassembled and tested at GSI, the
blower is ready to install upon
delivery. Standard wiring of the 3
hp motor eases the time of
installation. A control option is
available to utilize the dryer control
circuit to operate the Aspirator when
the dryer is in operation.
Motor side view of the 3 hp Blower for the Expanded Aspirator.
INSTALLATION
Mount the Blower Mounting
Bracket.
Remove the bolts on the dryer that will hold the
Blower Mounting Bracket
to the bulkhead.
Outside column: bolts 3, 4, 5, and 6 from the
bottom on the vertical seam.
Inside column: bolts 2, 3, 4, and 5 from the
bottom on the vertical seam.
Attach the
Blower Mounting Bracket
to the
bulkhead of the dryer using the bolts that were
removed.
Remove these bolts.
Place a
6" Compression Clamp
onto the end of the tube extending from
the settling chamber so the pipe edge is at the center of the clamp.
Tighten the first bolt at the pipe end of this clamp to hold it in place.
Insert a
90
°
° °
° °
Elbow
into the
6" Compression Clamp
so it points toward
the location of the fan.
Tighten the bolts of the clamp to hold the elbow in place.
Place a
6" Compression Clamp
onto the end of the
90
°
° °
° °
Elbow
.
Tighten the first bolt at the elbow end of this clamp to hold it in place.
Align the
3 hp Blower
and
T-valve Assembly
with the
90
°
° °
° °
Elbow
and the
Blower Mounting Bracket
.
Insert the bottom tube of the
T-valve Assembly
into the clamp on the elbow.
Bolt the
3 hp Blower
and
T-valve Assembly
to the
Blower Mounting
Bracket
with the
5/16" Whiz Nuts and Bolts
provided.
Note: Not all holes on the blower or mounting bracket are used. Align the
blower horizontally and vertically with the dryer.
Tighten the bolts of the clamp to hold the elbow to the T-valve Assembly.
Install the 90 ° Elbow and 6"
Compression Clamps for the
pipe from the settling chamber
to the blower.
Install the 3 hp Blower and T-
valve Assembly.
Wire the 3 hp Blower Unit.
Wire the
3 hp Blower Motor
according to the wiring diagram of the motor.