15
INSTALLATION
Installing the top pipe sections.
Expanded Aspirator
The Expanded Aspirator uses a
modified fill hopper box to pull debris
from the top auger as the dryer is
loaded. Debris is pulled up from the
fill box and then turned to fall to the
T-valve Assembly. The blower then
expels the particles to the cyclone for
collection.
The Expanded Aspirator pulls from the top auger.
Mount the Fill Hopper
Assembly.
Remove the existing
Fill Hopper
and the
Top
Auger Cover
directly in front of the hopper.
Bolt the
Fill Hopper Assembly
onto the top
auger at the same location as the original
hopper box using the bolts that were removed.
Measure the space in front of the box.
Cut the
Top Auger Cover
that was removed to this length.
Replace the modified
Top Auger Cover
onto the
Top Auger Housing.
Bolt the Fill Hopper Adapter
to the Fill Hopper Assembly.
Bolt the
Fill Hopper Adapter Weldment
to the
Fill Hopper Assembly
using the
5/16" Whiz
Nuts and Bolts
provided.
Install the 90° Elbow and 6"
Compression Clamps to the
Fill Hopper Adapter.
Slide a
6" Compression Clamp
over the
Fill
Hopper Adapter
so the tube is inserted to the
center of the clamp.
Tighten the bolt closest to the fill hopper box to
hold the clamp in place.
Insert a
90
°°°°°
Elbow
into the clamp, but leave loose.
Slide another
6" Compression Clamp
onto the elbow.
Tighten the bolt closest to the elbow to hold the clamp in place.
Fill Hopper Box
90° Elbow and Clamps