![GSI Group PNEG-369 Owner'S Manual Download Page 24](http://html1.mh-extra.com/html/gsi-group/pneg-369/pneg-369_owners-manual_2275196024.webp)
24
24' Batch & Autoflow
FC-4207516 16 GA.
BLUE
FC-4207518 18 GA.
ORANGE
FC-4207516 16 GA.
BLUE
FC-4207518 18 GA.
ORANGE
OFFSET JOINT
CONNECTION
DETAIL
3/8" DIA. HEX
FLANGED HEAD BOLT
(NO
SEALING WASHER)
USE 3/8" X 1.1/2"
BOLT, NUT AND
WASHER
SPLICE PLATE JOINT
(TOP VIEW)
STIFFENER INSTALLATION & LOCATION
When installing bottom stiffeners, you may find that in some cases the stiffener with base plate attached
will not rest on the foundation (due to unlevel concrete, etc.) Shim plates have been furnished and should be
used to fill opening between base plate and concrete.
IMPORTANT: If shim plates are not used where required, the downward pressure of the stiffeners will not
be transferred directly to the foundation, and bin failure could result.
FC-4206308 8 GA.
YELLOW
FC-42062 10 GA.
PURPLE
FC-42076
SPLICE
3/8" DIA. HEX FLANGED
HEAD BOLT (NO
SEALING WASHER)
Figure #12