7
I/O overview, MP handle
3 Product description
Instruction book, IQAN- LC5-X05
I/O overview, MP handle
Outputs
Digital
The IQAN-LC5-X05 MP handle has up to nine (9)
digital outputs
for use as command
signals..
Analogue
The IQAN-LC5-X05 MP handle has up to four (4) thumbwheel
analogue outputs
for
use as command signals..
MP handle outputs per thumbwheel.
(8) momentary button outputs B1 thru B8
(1) momentary trigger button outputs T1
(2) Primary analogue outputs OUT-W1A and OUT-W2A, 10%-90% Vs
(2) Secondary analogue outputs OUT-W1B and OUT-W2B, 90% - 10% Vs
POWER +5Vdc
OUT-W2A
OUT-W2B
GROUND
MP
OUT-W1A
OUT-W1B
B1
B
n
Vdc
out
90% Vs
50% Vs
10% Vs
-100%
100%
Neutral
position
Output A
Output B
Deflection