background image

KC-03.2 SPS

IMPORTANTE NOTE:

Read this manual carefully before installing or operating your wired remote controller. 

Make sure to save this manual for future reference.

Single Wired Controller

INSTALLATION AND OWNER’S MANUAL

Summary of Contents for Kaysun KC-03.2 SPS

Page 1: ...IMPORTANTE NOTE Read this manual carefully before installing or operating your wired remote controller Make sure to save this manual for future reference Single Wired Controller INSTALLATION AND OWNE...

Page 2: ...ion of the precautions that should be brought to your attention during operation To ensure the correct service of the wired controller read this manual carefully before using the unit Keep this manual...

Page 3: ...R KIT 14 5 SPECIFICATION 20 6 WIRED CONTROLLER FEATURES AND FUNCTIONS 21 7 WIRED CONTROLLER DISPLAY 22 8 WIRED CONTROLLER BUTTONS 23 9 PREPARATORY OPERATION 24 10 OPERATION 25 11 TIMER FUNCTIONS 31 12...

Page 4: ......

Page 5: ...or fire Reinstallation must be performed by professionals Do not uninstall the unit randomly Random uninstalling may lead to abnormal operation heating or fire of the air condition NOTE 1 Do not inst...

Page 6: ...you have been supply No Name Qty Remarks 1 Wire controller 1 2 Installation and owner s manual 1 3 Screws 3 M4X20 For Mounting on the Wall 4 Wall plugs 3 For Mounting on the Wall 5 Screws 2 M4X25 For...

Page 7: ...indoor unit 2 The wired controller works in a low voltage loop circuit Do not connect directly to 208 230V and 460V Do not wire this kind of wire into a loop Wiring clearance between the configured t...

Page 8: ...d Remote Controller Dimensions 2 Wiring Connection Diagram Wire controller red black yellow brown red black yellow brown Indoor unit mainboard Insert of the mainboard CN40 4 Core Shield Cable the leng...

Page 9: ...group from the mainboard with the male joint of the connective wires group See Fig 3 3 Connect the other side of the connective wires group with the male joint of the wires group leads from the wire...

Page 10: ...er part of the wire controller Fig 3 4 NOTE The PCB is mounted in the upper part of the wired controller Be careful not to damage the board with the screwdriver Slots Fig 3 4 5 Fasten the wire control...

Page 11: ...ort the wire controller s back pate by over tightening the mounting screws 6 Battery installation Place the battery in the unit and ensure the positive side of the battery is in accordance with the po...

Page 12: ...12 7 Wire the indoor unit There are three methods 1 from the rear 2 from the bottom 3 from the top 4 Notch the part of the wiring to pass through with a nipper tool...

Page 13: ...tach the wire controller s upper part While adjusting and mounting the upper case avoid clamping the wiring during installation Fig 3 9 Putty Putty Putty Trap Trap Trap Fig 3 8 Fig 3 9 IMPORTANT All t...

Page 14: ...14 4 APPENDIX INSTALL THE WIRE CONTROLLER KIT 1 Open the front panel 2 Disconnect the wire from the main controller board...

Page 15: ...he components From left to right the wired controller convert board and the display board 4 Identify connections on the Display Board CN201 is the display board connection to the main board wire on th...

Page 16: ...16 CN101 is the display board connection to the convert board wire on the display board 5 Uninstall the display board from the front panel Keep the display board holder...

Page 17: ...E Break off the upper left hand rectangle section with the two holes marked with a red rectangle 7 Replace the old display board for the New Display board provided and secure with the clips To uninsta...

Page 18: ...g mounting back on the Front Panel remove the display board s screen cover 9 Connect the Wires to the Adaptor Board a Connect the wire coming from the Display Board to the Convert Board this connectio...

Page 19: ...nection consists of 4 wires 10 Once the ports are connected install the cover 11 Mount the new display board and convert board to the Front Panel 12 Connect the wired remote controller to the display...

Page 20: ...CIFICATION Input voltage DC 12V Ambient temperature 23 110 F 5 43 C Ambient humidity RH40 RH90 Wiring specifications Wiring type Size Total length Shielded vinyl cord or cable 0 029in 0 74mm 0 75 1 25...

Page 21: ...AND FUNCTION OF THE WIRED CONTROLLER Feature LCD display Malfunction code display displays the error code helpful for servicing 4 way wire layout design Room temperature display Weekly Timer MODEL KC...

Page 22: ...r 4 Up down swing indicator 5 Panel function indicator 6 Main unit and secondary unit indicator 7 Follow me function indicator 8 Turbo Auxiliary Heat function indicator 9 C F indicator 10 Temperature...

Page 23: ...23 8 WIRED CONTROLLER BUTTONS 1 Mode 2 Power 3 Adjust 4 Fan speed 5 Swing 6 Timer 7 Day Off Del 8 Copy Follow me 9 Back Turbo 10 Confirm...

Page 24: ...Date setting is complete and the time setting is ready after pressing TIMER or if nothing is pressed in 10 seconds 4 Press or to set the current time Press repeatedly to adjust the current time in 1 m...

Page 25: ...ation mode Operation mode setting Press MODE to set the operation mode Heat function is invalid for cool only type unit Room temperature setting Press or to set the room temperature Indoor Setting Tem...

Page 26: ...the AUTO or DRY modes Room temperature sensor selection Press FOLLOW ME to select whether the room temperature is detected at the indoor unit or at the wired controller NOTE When the FOLLOW ME functio...

Page 27: ...keypad tone C F scale selection on some models Press BACK and COPY simultaneously for 3 seconds to alternate the temperature display between the F C scale Press LOCK for 3 seconds to activate the CHI...

Page 28: ...it sets to the highest fan speed setting to jump start the cooling process When the user presses TURBO in the HEAT mode for units with AUX HEAT the AUX HEAT activates and jump starts the heating proce...

Page 29: ...ight swing Press the SWING button to start Up Down swing function Press it again to stop When the Up Down swing function is activated the mark appears Press the SWING button to start Left Right swing...

Page 30: ...ppears Not applicable to all the models The operation can refer to the following instructions for the unit with four Up Down louvers can be operated individually 1 Press the SWING button to activate t...

Page 31: ...the air conditioner operation starts after the time has passed Off timer Use to stop the air conditioner operation The timer operates and the air conditioner operation stops after the time has passed...

Page 32: ...ess TIMER to select the or 2 Press CONFIRM and the Clock display flashes 3 Press or to set the time After the time is set the timer starts or stops automatically 4 Press CONFIRM again to finish the se...

Page 33: ...Off TIMER 1 Press TIMER to select the 2 Press CONFIRM and the Clock display flashes 3 Press the button or to set the On timer and then press CONFIRM 4 Press or to set the Off timer 5 Press CONFIRM to...

Page 34: ...tting of timer setting 1 Press or to select the day of the week and then press CONFIRM Press or to select the setting time The setting time mode temperature and fan speed appear on the LCD Press CONFI...

Page 35: ...s or to set the operation mode then press CONFIRM Press or to set the room temperature then press CONFIRM NOTE This setting is unavailable in the FAN or Off modes IMPORTANT Up to 8 scheduled events ca...

Page 36: ...repeating 3 through 8 Press or to set the fan speed then press CONFIRM NOTE This setting is unavailable in the AUTO DRY or OFF modes NOTE The weekly timer setting can be returned to the previous step...

Page 37: ...mer mode The TIMER mode can also be canceled by changing the timer mode using Timer To set the DAY OFF for a holiday Press TIMER to select the and then the timer starts automatically ex 1 After settin...

Page 38: ...s used for setup NOTE The DAY OFF setting is cancelled automatically after the set day has passed Copy out the setting in one day into the other day A scheduled event made once can be copied to anothe...

Page 39: ...to select the day to copy to 5 Press COPY to confirm Other days can be copied by repeating steps 4 and 5 Press CONFIRM to confirm the settings Press BACK to revert to the weekly timer The mark flashe...

Page 40: ...select the day of the week and the press CONFIRM 3 Press or to select the setting time want to delete The setting time mode temperature and fan speed appear on the LCD The setting time mode temperatur...

Page 41: ...and EMI comply with the CE certification requirements 13 AUTOMATIC PRESSURE SETTING 1 Make sure the test run is done with a dry coil If the coil is not dry run the unit for 2 hours in FAN ONLY mode to...

Page 42: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details QSXUI 014AEN 16117100A05335 20170724...

Page 43: ......

Page 44: ......

Reviews: