5
I/O overview, base
3 Product description
Instruction book, IQAN- LC5-X05
The IQAN-LC5-X05 control signals
The IQAN-LC5 is used to control the object in two directions:
•
the lever is moved to the right/left, direction X +/-.
•
the lever is moved forward/back, direction Y +/-.
The control signal is proportional to the lever's working range.
The control signal is transferred from the IQAN-LC5-X05 via a cable to the valve
driver electronics (i.e. IQAN-TOC2), an expansion module, or IQAN master unit.
The IQAN-LC5-X05 base has one Deutsch DTM connector, (C1), with 6 positions for
power and analogue output signals.
IQAN-LC5-X05 in a typical system
I/O overview, base
Outputs
The IQAN-LC5-X05 joystick has four (4)
analogue outputs
for use as command
signals..
IQAN-LC5-X05 outputs per axis.
(2) Primary analogue outputs OUT-XA and OUT-YA, 10%-90% Vs
(2) Secondary analogue outputs OUT-XB and OUT-YB, 90% - 10% Vs
CAN
Local I/O
IQAN-MD4
Expansion units
IQAN-LC5-X05 joysticks
POWER +5Vdc
OUT-YA
OUT-YB
GROUND
LC5
-X05
OUT-XA
OUT-XB
Vdc
out
90% Vs
50% Vs
10% Vs
-100%
100%
Neutral
position
Output A
Output B
Deflection