Water Softener
Weichwassermeister
®
GSX 5, GSX 10, GSX 10-I
Order no.-Nr. 075 187 970-inter Edited by: KONS-nkes-mrie G:\BA-187970-INTER_GSX 5-10.DOC
28
5.
During system deaeration, "Ibn" is indi-
cated in the display and after approx. 6
minutes - during the subsequent twin re-
generation – the time is displayed.
6.
Open the shut-off valve for soft water at
the connection block.
Note:
For detailed information on the handling of the control unit,
please refer to the operation card and chapter F, paragraph 2.2.
7.
Perform 0 °dH (0 °f, 0 mmol/l)test:
Unscrew the locking screw at the blending valve and close the
blending valve at the connection block completely (turn to the
right).
Withdraw a water sample downstream of the water softener and
determine the soft water hardness by means of the water test kit
„total hardness“.
The water softer is working properly if the measurement is
< 1 °dH (1,8 °f, 0,18 mmol/l).
The automatic start-up program takes about 45 minutes. During this
time, the system is deaerated, the brine tank automatically filled with
water and both exchangers are regenerated one after the other. During
the deaeration respectively during the regeneration, water flows
through the rinsing water hose to the drain.