Operation
47 | 76
BA_TD
3-
BS
00
0en
_07
4_sof
tli
Q
-S
C
.docx
Item
Designation
Item
Designation
1
Test tube
2
Titration solution
7.4.1
Taking a water sample
Note: If the flow rate is too low during the sampling, the result will be falsified.
● The system will be programmed with incorrect values for the raw water hardness.
● The required soft water value will not be attained.
► Fully open the water withdrawal point for cold water or the sampling valve. A flow
rate between 0.4 m³/h and 0.6 m³/h must be attained.
► When taking a soft water sample, the flow rate can be read in information level 2.
1.
Open a water withdrawal point for cold water.
a
In order to take a raw water sample, use a water withdrawal point for cold water
upstream of the system.
b
In order to take a soft water sample, use a water withdrawal point for cold water
downstream of the system.
2.
Let the water run for at least 30 seconds.
3.
Take a water sample with the test tube:
a
Fill the test tube up to the °dH mark to determine the water hardness in °dH.
b
Fill the test tube up to the marking °f (x 0.1 = mol/m³) in order to determine the
water hardness in °f, mol/m³ or mmol/l.
7.4.2
Determining the water hardness in °dH/°f
1.
Add one drop of titration solution (1 drop = 1 °dH or 1 °f).
2.
Shake the test tube until the titration solution is mixed with the water.
3.
In case of red colouring, repeat steps 1 and 2 and count the drops until the colour
changes to green.
2
1