Control unit
23 | 76
BA_TD
3-
BS
00
0en
_07
4_sof
tli
Q
-S
C
.docx
• Release of regeneration (factory-setting)
Start of a complete regeneration if the contact at the programmable input
closes.
• Regeneration lock
The regeneration is locked as long as the contact at the programmable input is
closed; manually released and automatic regenerations after a power failure
take priority.
• Fault signal forwarding
When the contact opens, a text stored using the myGrünbeck app is sent as an
e-mail.
If additional devices are connected in conjunction with the fault signal
forwarding function, it is possible to adapt the text stored in the myGrünbeck
app for sending emails accordingly.
4.5.2
Technical service level (Code 290)
In the technical service level, extended parameters and values can be changed.
● Selecting the time of regeneration
• Automatic (factory-setting)
• Fixed
● System type
• softliQ:SC18
• softliQ:SC23
• Free single system
● Soft water meter pulse rate
• Display only
● Regeneration water meter pulse rate
• Display only
● Perform double regeneration
• 0 (factory setting) or 1 (perform function). The factory setting (0) is reactivated
automatically upon completion of the function.
● Search for reference position of transfer valve
• 0 (factory setting) or 1 (perform function). The factory setting (0) is reactivated
automatically upon completion of the function.
● Search for reference position of regeneration valve
• 0 (factory setting) or 1 (perform function). The factory setting (0) is reactivated
automatically upon completion of the function.