8.3 Troubleshooting
Problem
Shine Pano cannot
communicate with
inverters via Rs485
Shine Pano cannot
communicate with
inverters via ZigBee
Shine Pano cannot
connect to the Shine
Server
1)Check the connection between inverter and Shine Pano
is OK, please refer to chapter 3.3.1. 2)Please confirm the
communication addresses don't repeat, and are in the
detecting range of the Shine Pano.
Please confirm the ID channel of ZigBee Module coincide
with that of the Shine Pano. If the communication is not OK
yet, please reconfigure the ZigBee Module referring to
corresponding user manual.
Note: ZigBee Module need to be purchased extra.
1
)
Make sure the Pano and router are in the same network
segment; 2
)
Confirm the parameter of the Pano about the
server coincides with the Shine Server, e.g. IP address,
domain name.
Rectification