background image

6

This GROHE fitting can be used in conjunction with 
a pressurised storage heater or an instantaneous heater.

Operation with unpressurised storage heaters 
( = open water heaters) is not possible.

To ensure correct operation of the fitting, the flow 
pressure should be between 1 and 5 bar.
It is recommendable to install a pressure-reducing valve 
in the case of higher flow pressures.

In the case of new installations, flush the cold 
and hot water lines thoroughly until the water is 
completely free of contamination. Otherwise any 
residues remaining in the lines may block the 
fitting and contaminate the drinking water.
Make sure that you do not damage the fitting 
surfaces with the tool during installation. For this 
reason, never use toothed pliers.

1

= Figure number

1

Installation on the worktop:

 Push escutcheon 

A

 

with O-ring 

B

 onto the fitting. Insert the fitting through 

the hole in worktop 

C

. Push on sealing washer 

D

 from 

below. Screw on nut 

F

 by turning connecting tube

clockwise.

2

Installation on the sink:

 Push escutcheon 

A

 with 

O-ring 

B

 onto the fitting. Insert the fitting through the 

hole in sink 

G

. Push on support plate 

and sealing 

washer 

D

 from below. Screw on nut 

F

 by turning 

connecting tube 

clockwise.

3

Insert fitting key 

H

 into connecting tube 

I

. Turn fitting 

key 

clockwise to fasten

 

mixer with nut 

B

.

4

Insert spray hose 

J

 through spout 

K

 and guide it 

through the mixer body from above. Insert spout 

K

 

until it snaps into place. Ensure that guide ring

is 

positioned. Screw pull out spray 

M

 onto spray hose 

J

 

without using any additional seals.
To ensure that pull out spray 

M

 is correctly seated 

when inserted, lug 

M1

 on the pull out spray must 

engage in the recess in spout 

K1

.

5

With pull out spray in position, push spring 

N

 onto 

spray hose 

J

 from below. Screw spray hose 

J

 onto 

union nut 

P

 with seal 

O

.

6

Ensure that you do not bend or twist the fitting 
pressure hoses.

7

Screw the fitting pressure hoses with the seal 

Q

 to the 

service valves.

Open the cold and hot water supply and check 
the connections for watertightness.

8

Operate the fitting as shown.

This fitting is equipped with a flow rate limiter, permitting 
an infinitely variable individual reduction in flow rate.
The highest possible flow rate is set at the factory before 
despatch.

The use of flow rate limiters in combination with 
hydraulic instantaneous heaters is not 
recommended.

9

Lever out the plug 

R

. Remove the set screw 

S

 using 

a 3mm allen key and remove the lever 

T

. Remove the 

cap 

U

.

0

Change the flow rate by turning the adjusting screw 
using a 2.5mm allen key.

Fault:

 Flow rate noticeably reduced or changed spray 

pattern
1. Insufficient supply pressure. Check the upstream 

installation.

2. Mousseur (13 967) blocked/dirty. Clean or replace 

the mousseur.

3. Non-return valve (08 565) blocked / dirty: Clean or 

replace the non-return valve.

Fault:

 Fitting housing leaking

1. Cartridge (46 048) screws loose. Tighten the cartridge 

screws alternately.

2. Seals at cartridge base damaged or dirt particles on 

sealing surfaces. Close the cold and hot water supply. 
Check and clean sealing surfaces, or replace 
cartridge completely.

3. Impermissible operating conditions, such as hot water 

temperature above 80 °C, pressure surges in 
upstream installation. Ensure that the operating 
conditions are in order. Replace cartridge completely 
if necessary.

Please contact your installer in the event of faults not 
described here.

For directions on care, please refer to the accompanying 
Care Instructions. Observe the valid national regulations 
when disposing of the fitting.

Prior to installation

Installation

, Page 3 + 4

Flow rate limitation

, Page 4

Troubleshooting

, Page 1 + 2

Care and recycling

GB

Summary of Contents for Flair 32 454

Page 1: ...NL 6 FIN 10 CZ 14 SK 18 EST 22 CN 26 F 3 S 7 PL 11 H 15 SLO 19 LV 23 RUS 27 E 4 DK 8 UAE 12 P 16 HR 20 LT 24 Flair 96 292 131 M 210828 11 07 Flair D 5 I 9 CZ 13 HR 17 GB 6 NL 10 H 14 RO 18 F 7 PL 11 P...

Page 2: ...2 1 28 32 454 32 455...

Page 3: ...4 3 1 A F B C D max 60mm E 2 G A B B E H max 45mm E 3 F H 21mm E G 3 8 19mm 5 N O P 13mm J 6 8 T S R U 3mm 10 2 5mm 2 5mm 11 max 80 C 7 19mm Q 4 L J K K1 M1 M 9...

Page 4: ...hrauben Sie den Brauseschlauch J unter Ver wendung der Dichtung O an die Anschlussmutter P 6 Achten Sie darauf dass Sie die Druckschl uche der Armatur nicht knicken oder verdrehen 7 Schrauben Sie die...

Page 5: ...osition push spring N onto spray hose J from below Screw spray hose J onto union nut P with seal O 6 Ensure that you do not bend or twist the fitting pressure hoses 7 Screw the fitting pressure hoses...

Page 6: ...le flexible de douche J Visser le flexible de douchette J sur l crou raccord P en pla ant un joint O 6 V rifier que les flexibles d alimentation de la robinetterie ne soient pas pli s ou tordus 7 Vis...

Page 7: ...onexi n P 6 Debe tenerse en cuenta que los flexos de conexi n de la grifer a no se doblen ni retuerzan 7 Atornillar los flexos de conexi n de la grifer a utilizando la junta Q a las llaves de paso Abr...

Page 8: ...vitare il flessibile doccia J al dado di raccordo P utilizzando la guarnizione O 6 Fare attenzione a non piegare o deformare i tubi flessibili a pressione del rubinetto 7 Avvitare i flessibili a press...

Page 9: ...onderen op de doucheslang J Schroef de doucheslang J met de pakking O op de aansluitmoer P 6 Voorkom dat de drukslangen van de kraan buigen of verdraaien 7 Schroef de drukslangen van de kraan met de p...

Page 10: ...rzy u yciu uszczelki O do nakr tki pod czeniowej P 6 Nale y zwr ci uwag na to aby przewody ci nieniowe nie zosta y zgi te lub skr cone 7 Przykr ci przewody ci nieniowe armatury z uszczelk Q do zawor w...

Page 11: ...12 GROHE 1 5 bar 1 0 1 C D F 2 G H D F 3 H I H B 4 J L M J 1 1 5 J J P 6 7 Q 8 9 R R 3mm S T 0 2 5mm 1 2 13 967 3 08 565 1 46 048 2 3 80 C 3 4 4 1 2 GR...

Page 12: ...ujte na p ipojovac matici P 6 Dbejte na to aby p itom nedo lo k zalomen i p eto en tlakov ch hadic armatury 7 Tlakov hadice armatury s t sn n m Q na roubujte na rohov ventily Otev ete ventily p vodu s...

Page 13: ...atlakoz any ra 6 gyeljen arra hogy a szerelv ny nyom t ml i ne t rjenek s csavarodjanak meg 7 Csavarozza a szerelv ny nyom t ml it a Q t m t s haszn lat val a sarokszelepekre Nyissa ki a hideg s a mel...

Page 14: ...icha de chuveiro J Apertar a bicha de chuveiro J porca de liga o P utilizando a veda o O 6 Prestar aten o para que os tubos flex veis de press o da misturadora n o se dobrem ou tor am 7 Apertar os tub...

Page 15: ...spodnje strani na cev prhe J Privijte cev prhe J s tesnilom O na priklju no matico P 6 Bodite pozorni na to da ne boste zavili ali prepognili tla ne cevi armature 7 Privijte tla no cev skupaj s tesnil...

Page 16: ...e crijevo tu a J s brtvom O na priklju nu maticu P 6 Pripazite da ne savinite ili ne zakrenete tla na crijeva armature 7 Uvijte tla na crijeva koriste i brtvilo Q na kutnom ventilu Otvorite dovod hlad...

Page 17: ...a de montaj P utiliz nd garnitura O 6 Ave i grij s nu ndoi i sau s r suci i furtunurile de presiune ale bateriei 7 n uruba i furtunurile de presiune pe ventilele col ar utiliz nd garnitura Q Deschide...

Page 18: ...19 GROHE c 1 5 1 0 1 A B C D F E 2 A B G H D F E 3 H I B H 4 J K K L M J M M1 K1 5 N J J P O 6 7 Q 8 9 R S 3 T U 0 2 5 1 2 13 967 3 08 565 1 46 048 2 3 80 C 3 4 4 1 2 RUS...

Page 19: ...20 Grohe AG 32 454 32 455 X X X X X X X X X X X X 3 95 4 15...