Technical data
56
Da
te of
is
sue :
Sept
ember
2012
Automatic Greasing System
TriPlus Trailer
F212157R02
7.2
Distribution blocks
Figure 7.2
Dimensions of the distribution block.
Maximum operating pressure
: 250bar
Operating temperature
: -20 ... +85 °C
Minimum number of doser segments
: 3 (excluding start and end segments)
Maximum number of doser segments
: 12 (excl. start and end segments)
Material
: galvanised steel
Material O-rings
: NBR
Grease inlet port thread
: M10 x 1 mm
Delivery per outlet type 45 (two per
segment)
: 0,045 cc
Delivery per outlet type 125 (two per
segment)
: 0,125 cc
Delivery per outlet type 200 (two per
segment)
: 0,200 cc
24
16
16
16
16
16
24
25
25
8
4
16,5
16,5
36
17
16
16
16
16
16
16
16
16
Summary of Contents for TriPlus Trailer