Automatic Greasing System
TriPlus Trailer
The GINA
25
Date of
is
sue :
Sept
e
m
ber
2
012
F212157R02
3.7
Diagnosis menu
Press <
diagnosis
>
The diagnosis menu shows various pieces of information
concerning the current status of the greasing system, such as
error messages and the status of its input and output
signals.
Press <F1> (
err
).
The screen shows the total number of times an overcurrent
or short-circuit has been detected in the circuit of the
electric motor of the pump unit.
Press <F2> (
rdgr
).
The screen shows the total number of time the relief valve
in the pump unit activated itself because the maximum
grease pressure was exceeded during a pump phase.
Press <F3> (
lowl
).
The screen shows the number of greasing cycles in which
the grease level switch in the reservoir reported a low
grease level.
Press <F4> (
rto
).
The screen shows the number of greasing cycles during
which the pump was disconnected by the control unit
because its drive shaft rotated too slowly or not at all.
Press <NEXT>.
The screen shows the end switch in the greasing system,
connected to the output port, did not send any or not
enough pulses to the control unit.
Press <F2> (
eres
).
DIAGNOSIS MENU
err I/O var tinfo
ERRORS
Pump over current
xxxxx
poc rdgr lowl rto
ERRORS
Release during grease
xxxxx
poc rdgr lowl rto
ERRORS
Low level
xxxxx
poc rdgr lowl rto
ERRORS
Revolution time out
xxxxx
poc rdgr lowl rto
ERRORS
End line switch
xxxxx
end1 eres pol
lol
Summary of Contents for TriPlus Trailer